通过对高压系统和低压系统进行全面分析,找出导致装置高负荷运行时低压系统超压而需放空的原因,提出具体的解决措施,实施后效果良好。
High pressure and low pressure system in urea plant were analyzed thoroughly to find out reasons leading to overpressure venting in low pressure system when the plant was running under heavy load. Practical measures were presented and the implementation result was proved to be perfect.
出处
《大氮肥》
CAS
2015年第2期116-118,121,共4页
Large Scale Nitrogenous Fertilizer Industry
关键词
合成转化率
汽提效率
氨碳比
高压调温水
低压调温水
conversion rate
stripping efficiency
ammonia carbon ratio
HP temperature adjusting water
LP temperature adjusting water