介绍了用气相色谱一质谱检测法测定食品包装材料中三(1,3-二氯丙基)磷酸酯含量的方法。试验结果表明:三(1,3-二氯丙基)磷酸酯的线性范围为0.1~50mg/L,检出限为0.04mg/kg,方法的加标回收率为92.5%~95.2%,相对标准偏差为2.50%~3.96%。
An analytical method for determination of Tris ( 1,3-diehloro-2-propyl ) Phosphate (TDCP) food packing materials was established by gas chromatography-mass spectrometry method. The linear ranges TDCP were 0.1 -50 mg/L, and the detection were 0.04mg/kg. The method recoveries were in the range 92.5% -95.2%, and the method precisions were 2.50% -3.96%. in of of
出处
《包装与食品机械》
CAS
2015年第3期70-72,共3页
Packaging and Food Machinery