期刊文献+

含铅污泥中Pb的激光诱导击穿光谱定量反演研究

Quantitative retrieval research of Pb in lead slime by laser induced breakdown spectroscopy
下载PDF
导出
摘要 为了实现含铅污泥中Pb的快速定量反演分析,选取PbⅠ:405.78nm为分析线,从谱线强度、信背比以及信号的相对标准偏差三方面研究了激光能量对含铅污泥中铅的激光诱导击穿光谱特性的影响。在23.1m J^135.4m J范围内,谱线强度随激光能量线性增加,信背比先增加后降低最终趋于稳定,信号的相对标准偏差随着激光能量的增加先减小后趋于稳定。配制了不同质量分数含铅污泥的样品,获得了铅的定标曲线。结果表明,在质量分数为0.001118~0.020115范围内,谱线强度与Pb含量之间有较好的线性关系,相关系数达到0.991;在此方法下,得到含铅污泥的Pb含量测量值与实际值之间的相对误差为8.72%。此方法能够实现含铅污泥中Pb的快速定量反演检测。 In order to achieve fast quantitative retrieval analysis of Pb in lead slime,PbⅠ:405. 78 nm was selected as the analytical line. The influences of laser energy on the laser induced breakdown spectroscopy characteristics of Pb in lead slime were discussed from three areas of spectral intensity,the ratio of signal and background and the relative standard deviation of signal. Within the range of 23. 1mJ - 135. 4mJ,line intensity increases linearly with the increase of laser energy,the ratio of signal and background increases at first and then decreases,and eventually stabilizes. The relative standard deviation of the signal decreases at first and then stabilizes with the increase of laser energy. The samples of lead slime with different mass fractions were prepared and the calibration curve of Pb was obtained. The results show that within the range of mass fraction of 0. 001118 - 0. 20115,spectrum intensity has the good linear relationship with Pb content. The correlation coefficient reaches 0. 991. With this method,the relative error between measurement value and real value of Pb content of lead slime is 8. 72%. This method can provide fast and quantitative retrieval measurement of Pb in lead slime.
出处 《激光技术》 CAS CSCD 北大核心 2015年第4期537-540,共4页 Laser Technology
基金 国家自然科学基金资助项目(61378041) 国家八六三高技术研究发展计划资助项目(2013AA065502 2014AA06A513) 安徽省杰出青年科学基金资助项目(1108085J19) 中国科学院仪器设备功能开发技术创新基金资助项目(yg2012071)
关键词 光谱学 激光诱导击穿光谱 含铅污泥 激光能量 定量反演分析 spectroscopy laser induced breakdown spectroscopy lead slime laser energy quantitative retrieval analysis
  • 相关文献

参考文献5

二级参考文献38

  • 1王传辉,戴琳,张先燚,姚关心,季学韩,凤尔银,郑荣儿,崔执凤.AlCl_3水溶液的激光诱导击穿光谱研究[J].中国激光,2006,33(9):1190-1194. 被引量:21
  • 2王智宏,汪家升.利用激光诱导击穿光谱技术定性分析矿石成分[J].中国科技信息,2007(9):21-22. 被引量:6
  • 3许洪光,管士成,傅院霞,张先燚,许新胜,季学韩,凤尔银,郑荣儿,崔执凤.土壤中微量重金属元素Pb的激光诱导击穿谱[J].中国激光,2007,34(4):577-581. 被引量:48
  • 4W. T. Y. Mohamed. Improved LIBS limit of detection of Be, Mg, Si, Mn, Fe and Cu in aluminum alloy samples using a portable Echelle spectrometer with ICCD camera. [J]. Opt. Laser Technol. , 2007, 40(1): 30-38.
  • 5S. Rosenwasser, G. Asimellis, B. Bromley et al.. Development of a method for automated quantitative analysis of ores using LIBS[J]. Spectrochirn. Acta Part B, 2001, 56(4) : 707-714.
  • 6Anglos, Demetrios. Laser-induced breakdown spectroscopy in art and archaeology[J]. Appl. Spectrosc. , 2001, 5S(6): 186A-305A.
  • 7G. Arca, A. Ciucci, V. Palleschi et al.. Trace element analysis in water by the laser-induced breakdown spectroscopy[J]. Appl. Spectrosc. , 1997, 51(8): 1102-1105.
  • 8L. Dudragne, P. Adam, J. Amouroux. Time-resolved laser-induced breakdown spectroscopy., application for qualitative and quantitative detection of fluorine, chlorine,sulfur, and carbon in air[J]. Appl. Spectrosc. , 1998, 52(10): 1321-1327.
  • 9R. A. Multari, L. E. Foster, D. A. Cremers et al.. Effect of sampling geometry on elemental emission in laser-induced breakdown speetroseopy[J]. Appl. Spectrosc. , 1996, 50(12) : 1483-1499.
  • 10F. Capitelli, F. Colao, M. R. Provenzano et al.. Determination of heavy metals in soils by Laser-induced Breakdown Spectroscopy[J]. Geoderma, 2002, 106(1): 45-62.

共引文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部