摘要 综述了利德华福高压变频器在攀钢提钒炼钢厂转炉区域的基本使用情况,以及点检、维护人员处理其故障时存在的问题。从利德华福高压变频器的主要结构原理、常见故障、经验故障、安全操作等方面分析了转炉区域利德华福高压变频器的故障诊断方法,为点检、维护人员提供了理论技术支撑和实际经验总结。 This paper summarizes the advantages improve the HARSVERT-A high voltage frequency converter at pan gang vanadium steel converter area of basic usage,and the tally,maintenance personnel to deal with the problem of the failure of.From the principles of main structure and improve the high pressure frequency converter,common fault,experience,and safety operation of converter is analyzed area and improve the fault diagnosis method of the high voltage frequency converter technology provides the theory support for the tally,maintenance personnel and practical experience.
作者 孙鹏
出处 《四川冶金》 CAS 2015年第3期45-50,共6页 Sichuan Metallurgy
关键词 利德华福高压变频器 功率单元 人机界面 常见故障 经验故障 HARSVERT-A high voltage frequency converter power unit human-computer interface common fault experience of failure