摘要 常压下用去离子水作为工质,在沸腾池底部单独或两两叠加地放置3种PPI的泡沫金属进行池内沸腾实验研究;分析了不同过热度下的热流密度和不同热流密度下池沸腾的传热系数;对沸腾汽泡在单层或双层泡沫金属表面产生、融合和脱离进行了可视化的研究。实验发现:不同PPI泡沫金属的叠加方式,会影响沸腾传热面积和产生汽泡的核心数,以及汽泡脱离受热壁面的动态特性。本实验为多孔介质池沸腾传热特性研究提供了实验指导和基础数据。 Deionized water is used as working medium in atmospheric pressure,and 3 kinds of PPI metal foams are placed alone or overlaid with each other in the bottom of the boiling vessel. The heat flow density under different degrees of superheat and pool boiling heat transfer coefficients under different heat flux were analyzed. The generation,fusion,separation processes of boiling bubbles on the surface of single or double metal foams were studied through visualization research. The result shows that different PPI metal foams overlay modes can affect the boiling heat transfer areas and the bubble- generate core numbers,as well as the bubbles' dynamic characteristics when separating from the heated wall. This experiment can provide guidance and basic data for the heat transfer characteristics of open- celled metal foams in pool boiling.
出处 《低温与超导》 CAS 北大核心 2015年第6期79-83,共5页 Cryogenics and Superconductivity
基金 国家自然科学基金(51276107) 交通部应用基础项目(2013319810150) 上海市教委创新科研课题(14ZZ142)
关键词 池内沸腾 金属泡沫 孔密度 沸腾汽泡 Pool boiling Metal foams Experiment Boiling bubble
  • 相关文献

参考文献1

二级参考文献21

  • 1过增元.当前国际传热界的热点--微电子器件的冷却.中国科学基金,1988,(2):20-25.
  • 2OHADI M. Thermal management of next genera- tion low volume complex electronics [EB/OL]. http://www, vita. com/cool/preS/08452Ohadi, pdf, 2003-05-13.
  • 3WANG Z, PENG X F, OCHTERBECK J M. Dy- namic bubble behavior during boiling in bead-packed structures [J]. Int J of Heat and Mass Transfer, 2004, 47:4771-4783.
  • 4MORI S, OKUYAMA K. Enhancement of the crit- ical heat flux in saturated pool boiling using honey- comb porous media [J]. Int J of Multiphase Flow, 2009, 35:946-951.
  • 5El-GENK M S, ALl A F. Enhanced nucleate boil- ing on copper micro-porous surfaces [J]. Int J of Multiphase Flow, 2010, 36 : 780-792.
  • 6LEE C Y, BHUIYA M M H, KIM K J. Pool boil- ing heat transfer with nano-porous surface [J]. Int J of Heat and Mass Transfer, 2010, 53: 4274- 4279.
  • 7FURBERG R, PALM B. Boiling heat transfer on a dendritic and micro-porous surface in R134a and FC- 72 [J]. Appl Therm Eng, 2011, 31:3595-3603.
  • 8LI C H, LI T, HODGINS P, etal. Comparison study of liquid replenishing impacts on critical heat flux and heat transfer coefficient of nucleate pool boiling on multi-scale modulated porous structures [J]. Int J of Heat and Mass Transfer, 2011, 54: 3146-3155.
  • 9ZHANG B J, KIM K J, YOON H. Enhanced heat transfer performance of alumina sponge-like nano- porous structures through surface wettability con- trol in nucleate pool boiling [J]. Int J of Heat and Mass Transfer, 2012, 557:487-7498.
  • 10FRANCO A, LATROFA E M, YAGOV V V. Heat transfer enhancement in pool boiling of a re- frigerant fluid with wire nets structures [J]. Exp Therm and Fluid Sci, 2006, 30:263-275.

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部