期刊文献+

PET/CT检查受检者有效剂量水平分析 被引量:2

原文传递
导出
摘要 目的分析影响PET/CT受检者有效剂量的各种因素,为降低受检者有效剂量寻求最佳的扫描条件。方法分别对受检者行PET/CT检查时的CT和PET有效剂量进行计算,在不影响图像质量的前提下,对CT和PET的扫描参数进行优化,使受检者接受的有效剂量降到最低。结果 CT管电压和管电流、PET检查时注射药物的剂量可以明显影响受检者有效剂量。结论根据不同受检者和疾病种类制定个性化的扫描方案,可以明显降低受检者的有效剂量水平。
出处 《中国辐射卫生》 2014年第6期507-509,共3页 Chinese Journal of Radiological Health
  • 相关文献

参考文献10

  • 1卢桂才,李鸿成,姬绪莉.一例PET-CT受检者体外剂量监测结果及思考[J].中国辐射卫生,2013,22(5):552-553. 被引量:3
  • 2Berrington de Gonzalez A, Darby S. Risk of cancer from diagnostic X - rays: estimates for the UK and 14 other countries J 1 Lancet, 2004, 363 (9406) :345 - 51.
  • 3Sodickson A, Baeyens PF, Andriole KP, et al. Recurrent CT, cumula- tive radiation exposure, and associated radiation -induced cancer risks from CT of adults[J]. Radiology, 2009, 251(1) :175 -184.
  • 4Huang B, Law MW, Khong PL. Whole -body PET/CT scanning estimation of radiation dose and cancer risk [J]. Radiology, 2009 251 ( 1 ) : 166 - 174.
  • 5Murano T, Iinuma T, Tateno Y, et al. Risk - benefit analysis of 18 FDG PET cancer screening[ J ]. Nippon Hoshasen Gijutsu Gakai Zasshi,2008,64(9) :1151 -6.
  • 6卢宁,汪静,乔宏庆,周谊,邓敬兰,李国权.^(18)F-FDG PET显像中受检者周围人员的辐射剂量监测[J].中华核医学杂志,2004,24(3):186-188. 被引量:23
  • 7黄海潮,魏伟奇,翁振乾,黄丽华,吴德龙,肖德涛.PET受检者出院后对公众照射剂量的估算与评价[J].中国辐射卫生,2008,17(2):175-176. 被引量:14
  • 8AAPM task group 23 of the diagnostic imaging council CT commit- tee. The measurement, reporting, and management of radiation dose in CT [ R ]. Washington : American Association of Physicists in Medicine, 2008.
  • 9ICRP. Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53. ICRP publication 80 approved by the Com- mission in September 1997[P]. Ann ICRP, 1998, 28:1.
  • 10Niven E, Nahmias C. Absorbed dose to very low bixth weight infants from 18Ffluorodeoxyglucose [ J ]. Health Phys, 2003, 84:307 - 316.

二级参考文献11

  • 1卢宁,汪静,乔宏庆,周谊,邓敬兰,李国权.^(18)F-FDG PET显像中受检者周围人员的辐射剂量监测[J].中华核医学杂志,2004,24(3):186-188. 被引量:23
  • 2陆克义,李险峰.甲状腺疾病患者^(131)I治疗后对他人的辐射危害评价[J].国外医学(放射医学核医学分册),2004,28(5):226-229. 被引量:9
  • 3GB18871-2002.电离辐射防护与辐射源安全基本标准[S].[S].,..
  • 4GBZ120-200,临床核医学卫生防护标准[S]
  • 5MOUNTFORD P J, O'DOHERTH M J, FORGE N I , et al. Estimation of close contact doses to Young infants from surface dose rates on radioactive adults [ J ]. Nuclear Medicine Communication 1987,8:857 - 863.
  • 6BECKERS C. , Regulations and policies on radioiodine 1311 therapy in Europe[J]Thyroid, 1997; 7:22 1 -224.
  • 7N. A. Benatar,B. F. Cronin,M. J. O’Doherty. Radiation dose rates from patients undergoing positron emission tomography: implications for technologists and waiting areas[J] 2000,European Journal of Nuclear Medicine(5):583~589
  • 8C. Chiesa,V. De Sanctis,F. Crippa,M. Schiavini,C. E. Fraigola,A. Bogni,C. Pascali,D. Decise,R. Marchesini,E. Bombardieri. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose[J] 1997,European Journal of Nuclear Medicine(11):1380~1389
  • 9黄海潮,魏伟奇,翁振乾,黄丽华,吴德龙,肖德涛.PET受检者出院后对公众照射剂量的估算与评价[J].中国辐射卫生,2008,17(2):175-176. 被引量:14
  • 10张晓懿,涂彧.甲亢患者^(131)I治疗后人体周围辐射场剂量分布[J].中国辐射卫生,2013,22(1):36-38. 被引量:3