摘要 越来越多的人受到睡眠质量欠佳的困扰,因此搭建一套简便、有效的睡眠脑电监测系统是十分必要的。它能够记录整晚睡眠脑电信息,进行自动睡眠分期,并且得到睡眠质量评分。系统采用单导联(三个电极)的简便方式进行采集,电极安放在前额叶,以防睡眠时脱落。分别采用了盘状电极和一次性心电图电极来采集睡眠脑电,以便为电极选择提供参考。振幅整合脑电图算法和样本熵算法被用于睡眠脑电处理中,结果显示两套算法都能进行自动睡眠分期与评价。本系统能够用于整晚睡眠监测和定量评价。 The growing rate of public health problem for increasing number of people afflicted with poor sleep quality suggests the importance of developing portable sleep electroencephalogram(EEG)monitoring systems.The system could record the overnight EEG signal,classify sleep stages automatically,and grade the sleep quality.We in our laboratory collected the signals in an easy way using a single channel with three electrodes which were placed in frontal position in case of the electrode drop-off during sleep.For a test,either silver disc electrodes or disposable medical electrocardiographic electrodes were used.Sleep EEG recorded by the two types of electrodes was compared to each other so as to find out which type was more suitable.Two algorithms were used for sleep EEG processing,i.e.amplitude-integrated EEG(aEEG)algorithm and sample entropy algorithm.Results showed that both algorithms could perform sleep stage classification and quality evaluation automatically.The present designed system could be used to monitor overnight sleep and provide quantitative evaluation.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2015年第3期548-552,557,共6页 Journal of Biomedical Engineering
基金 康复工程与健康科技深港联合创新平台基金项目资助(ZYB200907070060A)
关键词 睡眠脑电 采集系统 电极 睡眠分期算法 sleep electroencephalogram acquisition system electrode sleep staging algorithm
  • 相关文献

参考文献9

  • 1贺银方.多导睡眠图监测技术的发展与临床应用[J].现代电生理学杂志,2009,16(4):248-252. 被引量:11
  • 2BUYSSE D J, REYNOLDS C F, MONK T H, et al. The pittsburgh sleep quality index: a new instrument for psychiatric practice and research[J]. Psychiatry Research, 1989, 28(2): 193-213.
  • 3刘贤臣,唐茂芹,胡蕾,王爱祯,吴宏新,赵贵芳,高春霓,李万顺.匹兹堡睡眠质量指数的信度和效度研究[J].中华精神科杂志,1996,29(2):103-107. 被引量:3393
  • 4SHAMBROOM J R, FABREGAS S E, JOHNSTONE J. Vali- dation of an automated wireless system to monitor sleep in healthy adults[J].J Sleep Res, 2012, 21(2): 221-230.
  • 5张丹丹,丁海艳,刘云峰,叶大田.正常新生儿及婴儿睡眠振幅整合脑电图分析[J].清华大学学报(自然科学版),2009(3):428-431. 被引量:17
  • 6李慧.基于脑电分析的成人睡眠质量研究[D].北京:清华大学,2013.
  • 7RICHMAN J S, LAKE D E, MOORMAN J R. Sample entro- py [J]. Methods in Enzymology, 2004, 384: 172-184.
  • 8张丹丹.基于脑电分析的新生儿脑发育及脑损伤研究[D].北京:清华大学医学院,2010.
  • 9ABASOLO D, HORNERO R, ESPINO P, ALVAREZ D, et al. Entropy analysis of the EEG background activity in Alzhei- meres disease patients [J]. Physiol Meas, 2006, 27 (3):241- 253.

二级参考文献17

  • 1Maynard D E, Prior P F, Scott D F. Device for continuous monitoring of cerebral activity in resuscitated patients[J]. British Medical Journal, 1969:545 -546.
  • 2Viniker D A, Maynard D E, Scott D F. Cerebral function monitor studies in neonates [J]. Clin Electroencephalogr, 1984, 15(4): 185-192.
  • 3Verma U L, Archbald F, Tejani N A, et al. Cerebral function monitor in the neonate.Ⅰ: Normal patterns [J].Dev Med Child Neurol, 1984, 26(2):154 - 161.
  • 4Toet M C, Meij W, Vries L S, et al. Comparison between simultaneously recorded amplitude integrated EEG (Cerebral Function Monitor) and standard EEG in neonates [J].Pediatrics, 2002, 109(5): 772- 779.
  • 5Toet M C, Hellstrom-Westas L, Groenendaal F, et al. Amplitude integrated EEG at 3 and 6 hours after birth in fullterm neonates with hypoxic isehemic encephalopathy[J]. Arch Dis Child, 1999, 81(1): 19-23.
  • 6Hellstrom-Westas L, Rosen I, de Vries L S, et al. Amplitude-integrated EEG classification and interpretation in preterm and term infants [J]. NeoReviews, 2006, 7(2):76 - 87.
  • 7Osredkar D, Toet M C, van Rooij L G M, et al. Sleep-wake cycling on amplitude-integrated electroencephalography in term newborns with hypoxic-ischemic encephalopathy[J].Pediatrics, 2005, 115(2); 327-332.
  • 8Hellstrom-Westas L, Klette H, Thorngren-Jemeck K, et al. Early prediction of outcome with aEEG in premature infants with large intraventricular haemorrhages [J].Neuropediatrics, 2001, 32:319 - 324.
  • 9Maynard D E. A note on the nature of the non-rhythmic components of the electroencephalogram [J]. Activitas Nervosa Superior, 1969, 11 (3) : 238 - 241.
  • 10Cajochen C, Pischke J, Aeschbaeh D, et al. Heart rate dynamics during human sleep[J]. Physiol Behav, 1994, 55(4):769 - 774.

共引文献3418

同被引文献14

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部