期刊文献+

EMI认证测量中FFT接收机测量时间的注意事项 被引量:1

Timing Considerations using FFT-based Measuring Receivers for EMI Compliance Measurements
下载PDF
导出
摘要 引言 2010年6月,CISPR 16-1-1第3版第1修正案[1]规定,基于FFT的测量接收机(下简称FFT接收机)可用于电磁干扰认证测量,希望将扫描时间降低几个数量级,且不会降低测量准确度.FFT接收机在测量期间,通过在多个频率上并行计算,测量比分辨率带宽大得多的多个频谱段,如图1所示.与此相反,传统EMI接收机用给定的测量时间,在分辨率带宽内测量信号,因此对于整个频率范围需要较长的扫描时间.
作者 Jens Medler
出处 《安全与电磁兼容》 2015年第3期67-71,共5页 Safety & EMC
  • 相关文献

参考文献3

  • 1Amendmen! 1:2010-06 to C1SPR 16-1-1:2010-01 (Edition 3) Specification for radio disturbance and immunity measuring apparatus and meqhods - Par! 1-1: Radio dislurbance and immunily me~t,~uring apparatus - Measuring apparalus[S]. 2010.
  • 2Amendmenl 1:2010-06 to CISPR 16-2-3:2010-04 (Edition 3) Spec'ification f~r radio disturbance and immunity measuring apparalus and meihods - Parl 2-3: Melhods of measuremenl of dislnrhances and immunity - Radiated dislurhance measurements[S]. 2010.
  • 3MEI)LER. J. More speed, more insighl - Use of FFT-based EMI tesl receivers for EMI compliance measuremenls[J]. SAHqI'Y & EMC, 2013: 38-42.