期刊文献+

凝结水系统流动加速腐蚀处理方法的研究 被引量:2

Research on Treatment of the Condensate System of Flow Accelerated Corrosion
下载PDF
导出
摘要 针对当前部分超(超)临界机组凝结水系统所面临的流动加速腐蚀问题,从FAC产生机理出发,对影响FAC速率的因素进行总结,讨论抑制流动加速腐蚀的措施。针对超(超)临界机组因凝结水含氧量问题而发生FAC的现象,寻找合理的解决方案,即在凝结水系统中选取合理的部位,分别实施加氧处理和注入联氨。 In view of flow accelerated corrosion problems faced by the condensate system of the current part of the su-per (super)criticality unit, starting from the FAC mechanism to summarize the factors influencing FAC rate, discuss the measure to restrain the flow accelerated corrosion. In view of the phenomenon of FAC produced by oxygen content of conden-sation water in the super (super) criticality unit, looking for a reasonable solution, in other words,oxygen and hydrazine were injected respectively in the reasonable part of the condensate system.
出处 《发电与空调》 2015年第3期27-30,共4页
关键词 流动加速腐蚀 加氧处理 凝结水系统 flow accelerated corrosion oxygen treatment condensate system
  • 相关文献

参考文献5

  • 1荣幼澧.流动加速腐蚀的危害及其防止[J].华东电力,2003,31(3):50-51. 被引量:16
  • 2毕法森.李德勇.采用给水加氧处理抑制流动加速腐蚀[A].全国火电机组(600MW级)竞赛第8届年会论文集[c].2005.
  • 3刘朝阳.汽包锅炉给水加氧处理技术及应用条件分析[J].河北电力技术,2005,24(6):27-30. 被引量:9
  • 4Shunsuke Uehida , Masanori Naitoh. Evaluation of Wall Thinning Rate with the Coupled Model of Static Eleetrochemic~d Analysis and Dynamic Double Oxide Layer Analysis[J]. Nuclear Science and Technology.2009.46 ( 1 ):31~40.
  • 5Shunsuke Uchida , Masanori Naitoh. Evaluation of Flow Arrelerated Corrosion by Coupled Analysis of Corrosion and Flow Dynamirs[J].Nuclear Engineering and Design, 2010, ( 7 ) : 27-32.

二级参考文献1

  • 1DL805.4-2004.火电厂汽水化学导则第4部分:锅炉给水处理[S].[S].,..