期刊文献+

地下水渗流对地埋管周围土壤影响的模拟研究 被引量:1

Simulation Research about the Influence of Groundwater Seepage on the Soil Around Buried Pipe
下载PDF
导出
摘要 文章利用商业建模软件GAMBIT和FLURNT对垂直地埋管换热器与周围土壤换热进行了数值模拟,区别于以往的纯导热模型,文章基于饱和多孔介质和地下水流动理论,建立垂直地埋管换热器三维模型,模拟地下水渗流对垂直地埋管换热器周围土壤换热的影响。主要通过三维垂直单U型地埋管换热器的热渗耦合模型,研究在地下水渗流条件下,对周围土壤的影响。 The heat transfer between vertically buried pipe exchanger and soil surrounding is numerically simulated by business modeling software GAMBIT and FLURNT. Differing from the previous model with pure heat conduction,in this paper, the 3-D heat transfer model of buried pipe exchanger is established based on the theory of saturated porous media and groundwater flow ,to research the influence of groundwater seepage on the heat ex-change between vertically buried pipe and soil surrounding. The influence of groundwater seepage on the soil sur-rounding is studied mainly through the heat seepage coupled model of three-dimensional single U-shaped pipe which is vertically buried underground.
作者 郝桂珍 宋娇
出处 《发电与空调》 2015年第3期35-39,34,共6页
关键词 垂直地埋管换热器 地下水渗流 数值模拟 the U-vertical underground heat exchanger groundwater seepage numerical simulation
  • 相关文献

参考文献7

二级参考文献38

  • 1高青,李明,闫燕.群井地下换热系统初温和构造因素影响传热的研究[J].热科学与技术,2005,4(1):34-40. 被引量:15
  • 2韩慧民.土壤源热泵在中央空调系统中的应用[J].制冷空调与电力机械,2005,26(2):39-41. 被引量:5
  • 3刘猛,何雪冰,刘宪英.某住宅地源热泵系统夏季运行测试研究[J].暖通空调,2006,36(1):118-121. 被引量:6
  • 4顾中煊,吴玉庭,唐志伟,马重芳.U型管地下换热系统非稳态传热数值模拟[J].工程热物理学报,2006,27(2):313-315. 被引量:12
  • 5张旭.土壤源热泵的实验及相关基础理论研究[J].现代空调,2000,(3).
  • 6[1]Sulatisky M T, G van der Kamp. Ground-Source Heat Pumps in the Canadian Prairies. ASHRAE Transactions,1991, 97(1): 374-385
  • 7[2]Cane R L D, Forgas D A. Modeling of Ground-Source Heat Pump Performance. ASHRAE Transactions, 1991,97(1): 909-925
  • 8[3]Bose, J E. Soil and Rock Classification for the Design of Ground-Coupled Heat Pump Systems-Field Manual, Epri CU-6600. Oklahoma: International Ground Source Heat Pump Association, 1989. 29-33
  • 9[4]Yu Mingzhi, Fang Zhaohong. The Influence of Soil Freezing on Heat Transfer of Geothermal Heat Exchangers. In:Proc. of the International Conference on Power Engineering. Xi'an: TUP and Springer, 2001. 1442-1449
  • 10[5]Deerman J D, Kavanaugh S P. Simulation of Vertical U-tube Ground Coupled Heat Pump Systems Using the Cylindrical Heat Source Solution. ASHRAE Transactions, 1991, 97(1): 287-295