摘要
介绍根据粗大误差剔除法原理设计了一种低压电力线阻抗测量方法,对云南省一个典型的城乡结合部红土寨台区的低压集抄台区进行的测量,对80 k Hz^500 k Hz区间数据进行时域和频域的分析,得出整个低压电力线网络呈弱感性,电网分支的增加和用电器的接入式影响阻抗变化的主要因素,是造成抄表成功率低的重要因素。
According to the principle of gross error elimination method, a kind of low-voltage power line impedance measurement method was designed.In red walled area, a typical urban fringe of Yunnan, low-pressure collecting station is been measuring.A-nalysis of time domain and frequency domain on 80 kHz-500 kHz interval data, we have arrived at the conclusion that the low volt-age power line network is weak sensibility.To increase power grid branches and electrical appliances access is the main factor affect-ing the impedance change, and is also an important factor causing the low success rate of reading meter.
出处
《云南电力技术》
2015年第2期19-21,26,共4页
Yunnan Electric Power
关键词
粗大误差剔除法
低压电力载波
抄表成功率
阻抗
弱感性
gross error elimination method
low-voltage power line carrier
success rate of reading meter
impedance
weak sensi-bility