期刊文献+

影响心房颤动冷冻球囊消融术成功率的相关临床因素 被引量:3

原文传递
导出
摘要 冷冻球囊消融术可成功实现环肺静脉电隔离,治疗心房颤动,但其手术的成功率受多种因素影响。影响急性成功率的因素有球囊大小、封堵情况、鞘同轴、冷冻低温、二代球囊等;影响手术成功率的因素有患者基线特征、复温时间、冷冻次数、观察时间、迷走神经反应亢进、空白期复发等。对这些影响因素的了解有助于作出针对性的预防策略。
出处 《中国心脏起搏与心电生理杂志》 2015年第3期248-250,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
基金 上海市科委项目(14411961100)
  • 相关文献

参考文献24

  • 1凌天佑,吴立群.采用冷冻球囊消融治疗心房颤动的研究状况[J].中国心脏起搏与心电生理杂志,2014,28(3):270-272. 被引量:24
  • 2Packer DL, Kowal RC, Wheelan KR, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation : first results of the North American Arctic Front ( STOP AF) pivotal trial[ J]. J American Coll Cardiol,2013,61 (16) :1 713.
  • 3刘俊,唐闽,Kaufmann Jan,Kriatselis Charalampos,Fleck Eckart,李劲宏,方丕华,张澍.冷冻球囊消融与冷盐水灌注射频消融治疗阵发性心房颤动的长期随访效果比较[J].中国心脏起搏与心电生理杂志,2014,28(5):415-419. 被引量:12
  • 4Neumann T, Vogt J, Schumacher B, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study[ J]. J Am Coll Cardiol,2008 ,52(4) :273.
  • 5Vogt J,Heintze J, Gutleben KJ, et al. Long-term outcomes after cryoballoon pulmonary vein isolation : results from a prospective study in 605 patients[ J]. J Am Coll Cardiol,2013 ,61 ( 16) :1 707.
  • 6Knecht S, Kuhne M, Osswald S, et al. Quantitative assessment of a second-generation cryoballoon ablation catheter with new coolingtechnology-a perspective on potential implications on outcome[J]. Journal of Interventional Cardiac Electrophysiology, 2014,40¢1):17.
  • 7Malmborg H, Lonnerholm S, Blomstrom-Lundqvist C. Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation [ J ]. Europace’2008,10(11) :1 277.
  • 8Ghosh J,Martin A, Keech AC, et al. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation[ J]. Heart Rhythm, 2013,10(9) :1 311.
  • 9Andrade JG, Dubuc M, Guerra PG, et al. Cryoballoon ablation for atrial fibrillation[ J]. Indian Pacing and Electrophysiology Journal, 2012,12(2) :39.
  • 10FUmkranz A, Chun KRJ, Nuyens D, et al. Characterization of conduction recovery after pulmonary vein isolation using the “ single big cryoballoon” technique[ J]. Heart rhythm,2010,7(2) :184.

二级参考文献65

  • 1Andrade JG, Dubuc M, Guerra PG, et al. Cryoballoon ablation for atrial fibrillation [ J ]. Indian Pacing Electrophysiol J, 2012,12:39.
  • 2Andrade JG, Dubuc M, Guerra PG, et al. The biophysics and bio- mechanics of cryoballoon ablation[J]. Pacing Clin Electrophysiol, 2012,35:1 162.
  • 3Metzner A, Wissner E, Ouyang F,et al. Second-generation cryobal- loon ablation for paroxysmal atrial fibrillation : a step forward [ J ] ? Europace,2014,16(5 ) :621.
  • 4Khairy P, Dubuc M. Transcatheter cryoablation part I: preclinical experience [ J ]. Pacing Clin Electrophysiol, 2008,31 : 112.
  • 5Packer DL, Kowal RC, Wheelan KR, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) piyotal trial [ J ]. J Am Coil Cardiol,2013,61:1 713.
  • 6Andrade JG, Khairy P, Macle L, et al. Incidence and signiftcance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atri- al Fibrillation ( STOP AF) Trial[ J]. Circ Arrhythm Electrophysiol, 2014,7:69.
  • 7Andrade JG, Khairy P, Guerra PG, et al. Efficacy and safety of cryoballoon ablation for atrial fibrillation : a systematic review of pub- lished studies [ J ]. Heart Rhythm,2011,8 : 1 444.
  • 8Neumann T, Wojcik M, Berkowitsch A, et al. Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single proce- dure and predictors of success[ J]. Europace,2013,15 : 1 143.
  • 9Fumkranz A, Bordignon S, Schmidt B, et al. Improved procedural efficacy of pulmonary vein isolation using the novel second-genera- tion cryoballoon [ J ]. J Cardiovasc Electrophysiol,2013,24 : 492.
  • 10Chierchia GB, Di Giovanni G, Ciconte G, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow- up[J]. Europace,2014,16(5) :639.

共引文献39

同被引文献29

引证文献3

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部