摘要
机载计算机在系统上电时,1553B总线模块出现上电启动异常。从故障机理,时序逻辑和复位电路等方面分析,通过常温、高低温环境下的信号波形反复测试。分析定位为上电复位电路中的某电容导致上电复位信号爬升缓慢,产生抖动,引起1553B总线模块上电启动异常现象,对于此类现象采取有效措施,消除故障。
When the airborne computer at system up time, the 1553B data bus appear the start abnormal condition~ Analysis from the aspect of break down mechanism, the cycle time logic and reset electric circuit,test several times about the wave of the signal under normal,high and low temperature environment,After analyze,the reason for the abnormal was caused by an electric capacity in the wire reply an electric circuit up,the electric capacity caused the signal of start upset rise slowly,and also create trembles,and then the 1553B data bus show abnormal. Adopt valid measure to this kind of phenomenon, the cancellation break down.
出处
《大众科技》
2015年第6期10-12,共3页
Popular Science & Technology
基金
航空基金项目(2006ZC31002)
关键词
复位电路
上电启动
信号抖动
Reset electric circuit
last electricity start
signal trembles