摘要
在可燃液体储罐区总图布置中应正确理解规范条文的目的,切中规范条文的限制因素,灵活应用设计规范;综合考虑平面布置和竖向布置,平面布置的同时应该考虑好竖向布置的处理方式,使工程项目总体布局更合理、紧凑、美观;同时兼顾影响总图布置的众多因素,才能在满足相关规范的基础上,实现节约用地,减少投资的目的。结合工程实例,提出了可燃液体储罐区的总图布置优化措施。
In the flammable liquid storage tank area general layout arrangement,staff should correctly understand the purpose of the standard clauses;standard provision of limiting factors;flexible application design specification;incorporating the plane layout and vertical layout,and good vertical layout approach should be considered at the same time;make the project overall layout more reasonable;compact and beautiful;take the numerous influencing factors the general layout arrangement into account.On the basis of meeting the relevant specification,the economical use of land is realized and the purpose of reducing investment is attained.Combined with engineering example,this paper puts forward the general plan layout optimization measures in flammable liquid storage tanks.
出处
《新疆石油天然气》
CAS
2015年第2期94-96,6,共3页
Xinjiang Oil & Gas
关键词
可燃液体储罐区
总图布置
竖向布置
优化
节约用地
Flammable liquid storage tank area
General layout arrangement
Vertical layout
Optimization
Economical use of land