摘要 介绍了三亚阳光金融广场酒店客房、会所集中供应热水系统的设计,该工程采用了空气源热泵与太阳能联合(双热源系统)热水系统,详细介绍了各系统的设计计算方法,同时对酒店管理公司(Hyatt)的设计标准与国内相关规范的整合等进行了分析探讨,分析结果供超高层酒店集中供应热水系统设计参考。 The design of the central hot water system of Sanya Sunshine Plaza was introduced. Theair-source heat pump and solar energy (double-heat sources system ) were in the central hot water sys- tem. The design calculation method of the system was introduced. At the same time, the integration of the design standard of the hotel management company (Hyatt) and the domestic related codes was ana- lyzed and discussed to provide reference for the design of hot water systems in super high-rise buildings.
作者 王晓楠
出处 《中国给水排水》 CAS CSCD 北大核心 2015年第14期50-53,共4页 China Water & Wastewater
关键词 太阳能 空气源热泵 热水系统 超高层建筑 solar energy air-source heat pump hot water system super high-rise building
  • 相关文献

参考文献2

  • 1GB50015-2003,建筑给水排水设计规范(2009年版)[s].北京:中国计划出版社,2010.
  • 2GB50555--2010,民用建筑节水设计标准[S].北京:中国建筑工业出版社,2010.