摘要 A simple and sensitive kinetic-spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10-phenantroline as activator. The absorbance was measured at 525 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng ml-1of silver with good precision and accuracy, and the detection limit is down to0.125 ng ml-1. The relative standard deviation for a standard solution of 25.0 ng ml-1of silver is 1.36 %(n = 10).The proposed method proves to be highly sensitive,selective, and relatively rapid for the assay of silver at lowlevel range of 0.3–50.0 ng ml-1without any pre-concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory. A simple and sensitive kinetic-spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10-phenantroline as activator. The absorbance was measured at 525 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng ml-1of silver with good precision and accuracy, and the detection limit is down to0.125 ng ml-1. The relative standard deviation for a standard solution of 25.0 ng ml-1of silver is 1.36 %(n = 10).The proposed method proves to be highly sensitive,selective, and relatively rapid for the assay of silver at lowlevel range of 0.3–50.0 ng ml-1without any pre-concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory.
出处 《Rare Metals》 SCIE EI CAS CSCD 2014年第6期731-736,共6页 稀有金属(英文版)
基金 financially supported by the Ilam University
关键词 SILVER Kinetic-catalytic determination Azocarmine G ACTIVATOR 1 10-Phenantroline Silver Kinetic-catalytic determination Azocarmine G Activator 1,10-Phenantroline
  • 相关文献

参考文献28

  • 1Wang L, Liang AN, Chert HQ, Qi BB, Liu Y, Qian B, Fu J. Ultrasensitive determination of silver ion based on synchronous fluorescence spectroscopy with nanoparticles. Anal Chim Acta. 2008;616(2): 170.
  • 2Saeki S, Kubota M, Asami T. Determination of silver in soils by atomic absorption spectrometry. Water Air Soil Pollut. 1995;83: 253.
  • 3Dadfarnia S, Haji Shabani AM, Gohari M. Trace enrichment and determination of silver by immobilized DDTC microcolumn and flow injection atomic absorption spectrometry. Talanta. 2004; 64(3):682.
  • 4Bruland KW, Coale KH, Mart L, Analysis of seawater for dis- solved cadmium, copper and lead: an intercomparison of vol- tammetric and atomic absorption methods. Mar Chem. 1985; 17(4):285.
  • 5Boron MG, Herrin RT, Armstrong DE. The measurement of silver in road salt by electrothermal atomic absorption spec- trometry. Analyst. 2000; 125(1): 123.
  • 6Manzoori JL, Abdolmohammad-Zadeh H, Amjadi M. Ultra- trace determination of silver in water samples by electrothermal atomic absorption spectrometry after preconcentration with a ligand-less cloud point extraction methodology. J Hazard Mater. 2007;144(1-2):458.
  • 7Aruscavage PJY, Campbell E. The determination of silver in silicate rocks by electrothermal atomic absorption spectrometry. Anal Chim Acta. 1979;109(1):171.
  • 8Mohadesi A, Taher/VIA. Stripping voltammetric determination of silver(I) at carbon paste electrode modified with 3-amino-2- mercapto quinazolin-4(3H)-one. Talanta. 2007;71(2):615.
  • 9Li YH, Xie HQ, Zhou FQ. Alizarin violet modified carbon paste electrode for the determination of trace silver(I) by adsorptive voltammetry. Talanta. 2005;67(1):28.
  • 10Shervedani RK, Babadi MK. Application of 2-mercaptobenzo- thiazole self-assembled monolayer on polycrystalline gold electrode as a nanosensor for determination of Ag(I). Talanta. 2006;69(1):741.