摘要
目的 建立氯乙烯(VCM)生物标志物亚硫基二乙酸(TDGA)的气质联用仪(GC-MS)快速检测方法.方法 以温和新型甲酯化反应替代剧毒重氮甲酯化反应,并建立高灵敏度检测方法.结果 该方法标准曲线回归线性方程:y=8 460.5x-4758.2,线性系数为0.999 7,最低定量浓度2.0 μg/L,精密度为0.81%~2.38%,平均加标回收率为99.0%~102.9%.结论 该方法降低了传统甲酯化反应的风险,较气相色谱-火焰光度检测器(GC-FPD)法提高了检测灵敏度,满足亚硫基二乙酸的检测要求.
Objective To establish a rapid determination method with gas chromatography-mass spectrometer (GC-MS) for thiodiglycolic acid (TDGA),a vinyl chloride (VCM) biomarker.Methods A high-sensitivity determination method was established using a moderate methyl esterification instead of methyl esterification of highly toxic diazo reaction.Results The standard curve regression linear equation of the method was:y=8460.5x-4758.2,the linear coefficient was 0.999 7,the minimum quantity concentration was 2.0 μg/L,the range of precision value was 0.81%~2.38%,and the average recovery of standard addition was 99.0%~ 102.9%.Conclusion This method reduces the risk of traditional methyl esterification,improves the determination sensitivity compared with the GC-FPD method,and meets the determination requirement of TDGA.
出处
《中华劳动卫生职业病杂志》
CAS
CSCD
2015年第6期474-476,共3页
Chinese Journal of Industrial Hygiene and Occupational Diseases
基金
国家重点临床专科建设科研项目(财社[2011]170)
关键词
氯乙烯
生物标志物
亚硫基二乙酸
色谱法
气相-质谱
Vinyl chloride
Biomarker
Thiodiglycolic acid
Gas chromatography
Mass spectrometer