期刊文献+

冷轧辐射温度计测量误差分析 被引量:2

Error analysis of pyrometer used in cold mill plant
下载PDF
导出
摘要 辐射温度计是冷轧退火炉的关键设备,其测量误差会直接影响产品的性能,所以,有必要分析测量误差产生的因素。对辐射温度计的测量误差进行了分析和分类,从误差来源而言,可以分为标定误差、发射率误差、光学干扰误差、瞄准误差、背景辐射误差,其中,影响比较大的是发射率误差和背景辐射误差。同时,阐述了产生这些误差的原理,估计了各种误差的范围,并提出了减少误差的方法。 Pyrometer is the most important equipment of the annealing furnace, which measuring error effect the quality of the products. So it is necessary to analyse the factor of the measuring error. The errors of pyrometer used in furnace of cold mill plant can be classified into the error of calibration,the error of emissivity,the error of optical,the error of target aim and the error of background. Among them,the error of emissivity and the error of background has more influence.Meanwhile,the reason of these measuring error was claimed,the range of the error was evaluated,and the ways to decrease it was put forward.
作者 俞鸿毅 石燕
出处 《宝钢技术》 CAS 2015年第3期75-80,共6页 Baosteel Technology
关键词 辐射温度计 测量 误差 pyrometer measure error
  • 相关文献

参考文献6

二级参考文献24

  • 1田丰,李丰才,曹振江,仇振岳.光纤前置黑体空腔测温的非线性校正及温度补偿[J].基础自动化,1996,3(3):38-41. 被引量:2
  • 2段宇宁,赵琪,原遵东,P.Bloembergen R.Bosma.辐射源尺寸效应研究[J].计量学报,1996,17(3):161-166. 被引量:15
  • 3P. Bloembergen, Y. Duan, R. Bosma et al.. The characterisation of radiation thermometers subject to the size-of- sourceeffect[C]. Proc. of TEMPMEKO'96, 1996. 261-266.
  • 4P. Bloembergen. On the correction for the size-of-source effect corrupted by background radiation [ C]. Proc. TEMPMEKO 1999, 1999. 607-612.
  • 5G. Machin, M. Ibrahim. Size-of-source effect and temperature uncertainty: I high temperature systems [ C ]. Proc. TEMPMEKO 1999, 1999. 681-686.
  • 6G. Machin, M. Ibralim. Size of-source effect and temperature: II low temperature system [c]. Proc. TEMPMEKO 1999, 1999. 687-692.
  • 7P. Bloembergen, Y. Yamanda. The impact of the size-of-source effect on the uncertainty of fixed-point radiance temperatures a casestudy[C]. 2004. 1141-1148.
  • 8International Electrotechnical Commossion. IEC/TS 62492-1 2008-04. Industrial Process Control Devices-Radiation Thermometer Part 1 : Technical Data for Radiation Thermometers[S]. 2008.
  • 9D. Lowe, M. Battuello, G. Machinet al.. A comparison of size of source effect measurements of radiation thermometers between IMGC and NPL[C]. Temperature Its Measurement and Control in Science and Industry, 2003, 7:625-630.
  • 10G. Machin, R. Sergienko. A comparative study of size of source effect (SSE) determination techniques[C]. Proc. TEMPMEKO 2001, 2001. 155-160.

共引文献14

同被引文献5

引证文献2

二级引证文献1