期刊文献+

双侧锁定钛板与单侧锁定钛板治疗股骨远端骨折的疗效比较 被引量:7

Comparison of the efficacy of bilateral locking titanium plate and unilateral locking titanium plate for distal femoral fracture
下载PDF
导出
摘要 目的比较双侧锁定钛板与单侧锁定钛板内固定治疗股骨远端骨折的临床疗效。方法手术治疗53例股骨远端骨折患者,采用双侧锁定钛板固定(双侧组)24例,单侧锁定钛板固定(单侧组)29例。比较两组骨折愈合时间和术后膝关节功能。结果 53例均获随访,时间12~36个月。两组骨折愈合时间比较差异无统计学意义(P〉0.05)。术后3周及术后3个月膝关节屈伸活动度两组比较差异无统计学意义(P〉0.05),术后6个月膝关节屈伸活动度双侧组优于单侧组,差异有统计学意义(P〈0.05)。结论与单侧锁定钛板内固定相比,双侧锁定钛板固定术后并发症更少,术后6个月膝关节活动度更好。 Objective To compare the efficacy of bilateral locking titanium plate and unilateral locking titanium plate for distal femoral fracture. Methods 53 patients with distal femoral fracture were treated with bilateral locking titani- um plate in 24 cases and with unilateral locking titanium plate in 29 cases. Fracture healing time and postoperative knee function evaluation were compared. Results The patients were followed up for 12 ~ 36 months. There was no statistical significant difference in fracture healing time between two groups (P 〉 0. 05 ). There was no significant difference in the comparison of knee flexion and extension function 3 weeks after operation, 3 months after operation between the two groups ( P 〉 0.05 ). 6 months after operation, bilateral locking titanium plate group showed better knee flexion and extension function(P 〈 0. 05). Conclusions Comparing the two groups of locking titanium plate, using bilateral locking titanium plate for internal fixation materials lead to less postoperative complications, and pro- vide better knee flexion and extension function 6 months after operation.
出处 《临床骨科杂志》 2015年第3期331-334,共4页 Journal of Clinical Orthopaedics
关键词 股骨远端骨折 锁定钛板 内固定 distal femoral fracture locking titanium plate internal fixation
  • 相关文献

参考文献4

二级参考文献31

  • 1罗从风,姜锐,胡承方,皇甫小桥,曾炳芳.微创固定系统治疗膝关节周围复杂骨折[J].中华骨科杂志,2006,26(7):454-458. 被引量:46
  • 2刘璠,唐亮,茹江英,张驰.微创内固定系统治疗膝关节周围骨折[J].中华创伤骨科杂志,2006,8(10):949-953. 被引量:13
  • 3Rüedi T P,Buckley R E,Moran C G.骨折治疗的AO原则[M].2版.危杰,刘璠,吴新宝,等译.上海:上海科学技术出版社,2010:632.
  • 4Khalafi A, Curtiss S, Hazelwood S, et al. The effect of plate rotation on the stiffness of femoral LISS: a mechanical study. J Orthop Trauma,2006, 20(8): 542-546.
  • 5Zlowodzki M, Williamson S, Zardiackas LD, et al. Biomechanical evaluation of the less invasive stabilization system and the 95-degree angled blade plate for the internal fixation of distal femur Fractures in human cadaveric bones with high bone mineral density. J Trauma, 2006, 60(4): 836-840.
  • 6Schutz M, Schafer M, Bail H, et al. New osteosynthesis techniques for the treatment of distal femoral fractures. Zentralbl Chir, 2005, 130(4): 307-313.
  • 7Schutz M, Muller M, Regazzoni P, et al. Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study. Arch Orthop Trauma Surg, 2005, 125(2): 102-108.
  • 8Kregor PI, Stannard JA, Zlowodzki M, et al. Treatment of distal femur fractures using the less invasivc stabilization system: surgical experience and early clinical results in 103 fractures. J Orthop Trauma, 2004, 18(8): 509-520.
  • 9Markmiller M, Konrad G, Sudkamp N. Femur-LISS and distal femoral nail for fixation of distal femoral fractures: are there differences in outcome and complications? Clin Orthop Relat Res, 2004, (426): 252-257.
  • 10荣国威.骨折治疗的AO原则.北京:华夏出版社,2003:25-26.

共引文献44

同被引文献34

引证文献7

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部