期刊文献+

心衰标志物可视化联合检测方法研究 被引量:7

Rapid Visual Immunoassay of Multi-biomarker for Heart Failure Based on Magnetic Particles Images
下载PDF
导出
摘要 基于夹心免疫原理和表面免疫吸附模型,采用Image Pro Plus软件对硅片表面磁颗粒分布图像进行定量化处理,建立了硅片表面心衰标志物可视化联合检测方法。研究表明,该方法从抗体包被到获得检测结果不超过1h,操作简单,在单张硅片上可实现心衰标志物NT_proBNP和cTnI的联合检测。NT—proBNP和cTnI的最低检出限分别为21.8pg/mL和0.034ng/mL,检测范围分别为21.8-40000pg/mL和0.034~50ng/mL。83例不同程度心血管疾病患者的血清样本的检测结果与商品化免疫分析仪检测结果一致,相关系数r〉0.98。因此,该快速免疫检测方法可以满足临床检测心衰标志物的需要。 Based on sandwich immunoassay, immuno-adsorption model and quantitative anal particles image on the surface of silicon chip, rapid immunoassay of multi-biomarkers for heart ysis of magnetic failure had been established. This method is simple and rapid compared to traditional ELISA. The assay time does not exceed 1 hour from antibody immobilization to final results obtained. In addition, it was easy to realize a joint measurement for NT-proBNP and cTnI on single silicon biochip. The limits of detection for NT-proBNP and cTnI were 21.8 pg/mL and 0. 034 ng/mL, and the detection ranges were 21.8 - 40000 pg/mL and 0. 034 - 50 ng/mL, respectively. The assay results for NT proBNP and cTnlwere compared using 83 serum samples from patients with different cardiovascular diseases with those on commercial analyzers and obtained a very good correlation (r〉0.98). In conclusion, this rapid visual immunoassay is well suitable for the clinical detection of heart failure biomarkers.
出处 《影像科学与光化学》 CAS CSCD 北大核心 2015年第4期275-284,共10页 Imaging Science and Photochemistry
基金 国家科技支撑计划(2013BAI03B)资助
关键词 硅生物芯片 可视化 免疫检测方法 心衰 生物标志物 silicon biochip visualization immunoassay heart failure biomarker
  • 相关文献

参考文献10

  • 1Engvall E, Perlmann P. Enzyme linked immunosorbent assay(ELISA) quantitative assay of immunoglobulin G [J]. Immunochemistry, 1971, 8(9) : 871 874.
  • 2Van Weemen B K, Sehuurs A H W M. Immunoassay using antigewenzyme conjugates [J]. FEBS Letters, 1971, 15 (3): 232-236.
  • 3Wild D. The Immunoassay Handbook [M~. Gulf Profes sional Publishing, 2005.
  • 4Lloyd J D, Adams R J, Brown T M. , Carnethon M, Dai S, De Simone G, Ferguson T B, Ford E, Furie K, Gillespie C. Heart disease and stroke statistics-2010 update a report from the American Heart Association [J]. Circulation, 2010, 121(7): e46 e215.
  • 5Seino Y, Ogawa A, Yamashita T, Fukushima M, Ogata K I, Fukumoto H, Takano T. Application of NT-proBNP and BNP measurements in cardiac care: a more discerning marker for the detection and evaluation of heart failure [J]. European Journal of Heart Failure, 2004, 6(3) : 295.
  • 6Horwich T B, Patel J, MacLellan W R, Fonarow G C. Cardiac troponin I is associated with impaired hemodynamics, progressive left ventricular dysfunction, and increased mor- tality rates in advanced heart failure [J]. Circulation, 2003, 108(7) : 833-888.
  • 7Peacock IV W. F, De Marco T, Fonarow G C, Diercks D,Wynne J, Apple F S,Wu A H. Cardiac troponin and outcome in acute heart failure [J]. New England Journal of Medi- cine, 2008, 358(20): 2117 2126.
  • 8ELISA EM~. http://en, wikipedia, org/wiki/ELISA ~ Sand- wich ELISA. 2015.
  • 9Neuendorf K A. The Content Analysis Guidebook [M]. Sage Publications Thousand Oaks, CA, 2002.
  • 10Wang S X,Gaster R S,Xu L,Han S J,Wilson R. Magnetic Sensor Based Quantitative Binding Kinetics Analysis [M]. Google Patents. 2011.

同被引文献57

引证文献7

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部