期刊文献+

生物质电厂高温过热器爆管原因分析 被引量:2

Cause Analysis on Tube Explosion of High-Temperature Superheater in a Biomass Power Plant
下载PDF
导出
摘要 通过对生物质电厂高温过热器爆管进行金相分析,发现高温过热器管存在不同程度的晶间腐蚀,而爆漏弯头由于晶粒粗大,加速了晶间腐蚀速率。针对此问题提出了进一步开展防腐试验的建议。 Through the metallographic analysis of the explosive tube,this paper analyzes that the High-Temperature Superheater exists inter-crystalline corrosion on different levels in a biomass power plant,and because of explosive elbow exists grain coarsening, speeds up the rate of inter-crystalline corrosion.This paper has put forward a further suggestion of anticorrosion test to this problem.
作者 李俊超 林丁
出处 《机电工程技术》 2015年第6期163-166,共4页 Mechanical & Electrical Engineering Technology
关键词 生物质锅炉 316不锈钢 金相分析 晶间腐蚀 biomass-fired boiler 316 stainless steel metallographic analysis inter-crystalline corrosion
  • 相关文献

参考文献3

二级参考文献25

  • 1冯砚厅,某生物发电有限公司锅炉过热器大面积腐蚀原因分析技术报告,河北省电力公司锅炉压力容器检验中心,2008年.
  • 2Soren Knudsen Ker. Modeling deposit formation in straw - fired grate boilers. Institute of energy technology ACOMP research group, Aalborg University.
  • 3Rudolf Riedl, Jonas Dahl. Corrosion in fire tube boiler of biomass eombustion plants. Proceedings of the China international Corrosion Control Conferenee 99, paper Nr. 90129, October 1999.
  • 4Hanne Philbert Michelsen, Flemming Frandsen. Deposition and high temperature corrosion in a 10MW straw fired boiler. Fuel Processing Technology 1998 (54) :95 - 108.
  • 5Miltner A,Beckmann G,Freidl A. Preventing the chlorine-induced high temperature corrosion in power boilers without loss of electrical efficiency in steam cycles[J].Applied Thermal Engineering,2006,(26):2005-2011.
  • 6Brostrom M,Kassman H,Helgesson A. Sulfation of corrosive alkali chlorides by ammonium sulfate in a biomass fired CFB boiler[J].Fuel Processing Technology,2007,(88):1171-1777.doi:10.1016/j.fuproc.2007.06.023.
  • 7Henderson P,Szakalos P,Pettersson R. Reducing superheater corrosion in wood-fired boilers[J].Materials and Corrosion,2006,(02):128-134.
  • 8Cha S C,Spiegel M. Local reactions of KCl particles with iron,nickel and chromium surfaces[J].Materials and Corrosion,2006,(02):159-164.
  • 9Sandberg J,Kalsson C,Fdhila R B. A 7 year long measurement period investigating the correlation of corrosion,deposit and fuel in a biomass fired circulated fluidized bed boiler[J].Applied Energy,2011,(88):99-110.
  • 10Aho M,Vainikka P,Taipale R. Effective new chemicals to prevent corrosion due to chlorine in power plant superheaters[J].Fuel,2008,(87):647-654.doi:10.1016/j.fuel.2007.05.033.