期刊文献+

Compound Pendulum Modeling and Resonant Frequency Analysis of the Lower Limbs for the Wearer and Exoskeleton 被引量:2

Compound Pendulum Modeling and Resonant Frequency Analysis of the Lower Limbs for the Wearer and Exoskeleton
原文传递
导出
摘要 An innovative lower extremity exoskeleton with hybrid leg structures is proposed in this paper. The compound pendulum model is applied to analyze the swing motion during walking for the wearer and the exoskeleton respectively. The expression of the resonant period for the human lower limb is obtained and the optimum stride frequency, at which the energy expenditure for walking is the least, coincides with the stride frequency of strolling well. As for the exoskeleton, the relationship between the inertial parameters and the resonant period of the hybrid leg is established. To minimize the walking energy cost for the exoskeleton, the inertial parameter design must guarantee that the resonant period of the hybrid leg coincides with the actual stride period of the wearer. The resonant period of the hybrid leg is also influenced by the scissor angle which determines the distance between the hip and the ankle of the lower extremity exoskeleton (SJTU-EX) and can be adjusted to match different stride frequencies of various motions by the proper scissor angle planning. An innovative lower extremity exoskeleton with hybrid leg structures is proposed in this paper. The compound pendulum model is applied to analyze the swing motion during walking for the wearer and the exoskeleton respectively. The expression of the resonant period for the human lower limb is obtained and the optimum stride frequency, at which the energy expenditure for walking is the least, coincides with the stride frequency of strolling well. As for the exoskeleton, the relationship between the inertial parameters and the resonant period of the hybrid leg is established. To minimize the walking energy cost for the exoskeleton, the inertial parameter design must guarantee that the resonant period of the hybrid leg coincides with the actual stride period of the wearer. The resonant period of the hybrid leg is also influenced by the scissor angle which determines the distance between the hip and the ankle of the lower extremity exoskeleton (SJTU-EX) and can be adjusted to match different stride frequencies of various motions by the proper scissor angle planning.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2015年第3期372-381,共10页 仿生工程学报(英文版)
关键词 compound pendulum EXOSKELETON inertial parameter stride frequency compound pendulum, exoskeleton, inertial parameter, stride frequency
  • 相关文献

参考文献2

二级参考文献24

  • 1JiaLun Yang, Feng Gao, ZhenLin Jin,LiFeng Shi.Classification of lying states for the humanoid robot SJTU-HR1[J].Science China(Technological Sciences),2009,52(5):1301-1311. 被引量:1
  • 2Glynn A, Fiddler H. The Physiotherapists Pocket Guide to Exercise: As-Sessment, Prescription and Training, Elsevier, Churchhill Livingstone, 2009.
  • 3Hoppenfeld S, Murthy V L. Treatment and Rehabilitation of Fractures, Lippincott Williams & Wilkins, Philadelphia, USA, 1999.
  • 4Goffer A. Gait-locomotor apparatus,[2006-12-26], Patent US 7153242, https:lldata.epo.org/gpi/EPI260201 B I-Gait- locomotor-apparatus.
  • 5Kawamoto H, Hayashi 1; Sakurai 1; Eguchi K, Sankai Y Development of single leg version of hal for hemiplegia. Proceedings of the 31st Annual International Conference of the IEEE Engineering ittMedicine and Biology Society, Minneapolis, Minnesota, USA, 2009, 5038-5043.
  • 6Seo K H, Lee J J. The development of two mobile gait rehabilitation systems, IEEE Transactions on Neural Sys?tems and Rehabilitation Engi- neering, 2009, 17, 156- I 66.
  • 7Bouri M, Gall B L, Clavel R. A new concept of parallel robot for rehabilitation and fitness: The lambda. Proceedings of the IEEE International Conference on Robotics and Biomimetics, GuiIin, China, 2009, 2503-2508.
  • 8Homma K, Fukuda 0, Sugawara J, Nagata);' Usuba M. A wiredriven leg rehabilitation system: Development of a 4-DOF experimental system. Proceedings of the Interna?tional Conference on Advanced Intelligent Mechatronics, Port Island, Japan, 2003,908-913.
  • 9Nikitczuk J, Weinberg B, Canavan PK, Mavroidis C. Active knee rehabilitation orthotic device with variable damping characteristics implemented via an electrorheological fluid. IEEEIASME Transactions on Mechatronics, 2010, 15, 952-960.
  • 10Kikuchi T, Oda K, Furusho J. Leg-robot for demonstration of spastic movements of brain-injured patients with compact magnetorheological fluid clutch. Advanced Robotics, 2010, 24,671-686.

共引文献9

同被引文献3

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部