某600 MW机组在B级检修后出现轴封供汽母管温度大幅度波动现象,直接影响了机组运行安全性。通过详细分析找到了问题原因,提出了运行维护措施以及技术改造方案以供工程应用参考。
It is the temperature fluctuation of seal steam in A 600 MW unit after the B level overhaul, and it directly affects the safety of the unit operation. We find the cause through detailed analysis, and propose operation maintenance measures and technical reformation scheme. This is a reference for the application of Engineering Technology.
出处
《应用能源技术》
2015年第7期21-23,共3页
Applied Energy Technology