期刊文献+

应进一步重视经冷冻消融治疗快速心律失常安全性与有效性远期结果的研究 被引量:1

Paying sufficient attention to the studies on the long-term safety and efficacy of cryoablation of tachyarrhythmias
原文传递
导出
摘要 经冷冻消融治疗快速心律失常己用于临床,尤其是对心房颤动(房颤)、中间隔旁路旧0的消融已积累了初步经验,这些经验提示:①经冷冻球囊导管消融房颤与经导管消融房颤的急性成功率相似,随访2年的成功率相近(63.2%对57.3%,P=0.25);(参较之于射频消融房颤,冻冷消融房颤时膈神经麻痹的发生率高(2.1%对0);③大多数报道提示,上述两种能源的消融时间、透视时间以冷冻能为短,但也有延长的报道H0;④冷冻消融中间隔旁路其导管稳定性较好,房室阻滞并发症较低。
作者 黄从新
出处 《中华心律失常学杂志》 2015年第3期161-161,共1页 Chinese Journal of Cardiac Arrhythmias
  • 相关文献

参考文献4

  • 1黄从新.冷冻球囊导管消融治疗心房颤动的研究进展[J].中华心律失常学杂志,2015,19(3):189-191. 被引量:9
  • 2Atienza F, Arenal A,Torrecilla EG, et al. Acute and Long-term out- come of transvenous cryoablation of midseptal and parahissian ac- cessory pathways in patients at high risk of atrioventricular block during radiofrequency ablation [ J ]. Am J Cardiol,2004,93 : 1302- 1305.
  • 3Mugnai G, Ghierehia GB, de Asmundis C, et al. Comparison of pul- monary vein isolation using eryoballoon versus conventional radio- frequency for paroxysmal atrial fibrillation [ J ]. Am J Cardiol, 2014,113 : 1059-1513.
  • 4Sehmidt M, Dorwarth U, Andresen D, et al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry[ J]. J Cardiovasc Electrophysio1,2014,25 : 1-7.

二级参考文献21

  • 1Kuck KH, Fiimkranz A. Cryaballoon ablation of atrial fibrillation [ J ]. J Cardiovase Electmphysio1,2010,21 : 1427-143.
  • 2Wadhwa MK, Rabme MM, Dobak J, et al. Transoatheter eryoabla- tion of ventricular myocardium in dogs [ J ]. J Interv Card Electro- physio1,2000 ,4 :537-545.
  • 3Andrade JG, Khairy P, Guerra PG, et al. Efficacy and safety of cryo- balloon ablation for atrial fibrillation: a systematic review of pub- lished studies [ J ]. Heart Rhythm,2011,8 : 1444-1451.
  • 4Calkins H, Reynolds MR, Spector P, et al. Treatment of atrial fibril- lation with antiarrhythmie drugs or radiofrequency ablation: two systematic literature reviews and meta-analyses [ J ]. Cire Arrhythm Etectrophysiol, 2009,2 : 349 -361.
  • 5Sehmidt M, Dorwarth U, Andresen D, et al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry[J]. J Cardiovasc Electrophysiol,2014,25:1-7.
  • 6Mugnai G, Chierehia GB, de Asmundis C, et al. Comparison of pul- monary vein isolation using cryoballoon versus conventional radio- frequency for paroxysmal atrial fibrillation[ J]. Am J Cardio1,2014, 113:1509-1513.
  • 7Packer DL, Kowal RC, Wheelan KR, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation : first results of the North American Arctic Front l.(STOP AF) pivotal trial [ J ]. J Am.Coil Cardiol,2013 ,61:1713-1723.
  • 8Vogt J, Heintze J, Gutleben K J, et al. Long-term outcomes after cryaballoon pulmonary vein isolation: results from a prospective study in 605 patients[ J]. J Am Coil Cardiol,2013 ,61:1707-1712.
  • 9Neumann T, W6jcik M, Berkowitsch A, et al. Cryoballoon ablation of paroxysmal atrial fibrillation : 5-year outcome after single proce: dnre and predictors of success [ J ]. Europace, 2013, 15 : 1143- 1149.
  • 10Ouyang F,Tilz R, Chun J, et al. Long-term results of catheter abla- tion in paroxysmal atrial fibrillation : lessons from a 5-year follow- up[ J ]. Circulation ,2010,122:2368-2377.

共引文献8

同被引文献3

引证文献1

二级引证文献3