摘要
英格索兰压缩机在实际生产中发生因冷却后温度高导致运行效率下降,甚至影响设备稳定正常运行。因为放散阀微漏、管网用量变化大导致气体放散运行效率下降。查找以上问题原因,介绍了英格索兰氮压机长周期高效运行几点实践。
Due to high temperature after cooling the Ingersoll Rand compressor suffered lower operating efficiency during actual production, which even affected normal stable operation of the equipment. Slight leakage of the blow- off valve and big changes in network consumption reduced gas release efficiency. The causes of above problems were found out and practices of long- term high- efficiency operation of Ingersoll Rand nitrogen compressor are introduced.
出处
《冶金动力》
2015年第8期29-30,共2页
Metallurgical Power
关键词
英格索兰
氮气压缩机
长周期
高效运行
Ingersoll Rand
nitrogen compressor
long term
high-efficiency operation