锅炉汽包与过热器压差大的原因分析及处理 被引量:7

Cause Analysis and Treatment of Excessive Pressure Difference between Boiler Drum and Superheater
下载PDF
导出
摘要 涟钢一台150 t/h煤气锅炉因喷水减温器内弹簧片损坏,堵住两个蒸汽出口导致汽包与过热器压差增大,对此进行了原因分析,提出了处理措施,总结了处理此类故障的经验。 Damaged leaf spring in the spray type desuperheater of a 150t/h gas-fired boiler at Lianyuan Steel blocked the two steam exits, causing excessive pressure difference between the drum and superheater. The causes of the problem were analyzed, treatment mea-sures were provided and experience in solving such problems was also summarized.
出处 《冶金动力》 2015年第8期54-56,共3页 Metallurgical Power
关键词 锅炉 汽包 过热器 喷水减温器 boiler drum superheater spray desuperheater pressure difference