摘要
介绍了某厂360M2环冷机设备在试运行阶段发生的不正常颤动故障,查找分析问题原因,针对此问题,在环冷机制作、安装、使用及维护方面提出了处理措施及有关要求。
The fault of abnormal vibration during commissioning of Model 360m^2 sintering circular cooler was described.The cause of the problems was identified and analyzed.Treatment measures and relevant requirements were proposed to deal with manufacturing,installation,operation and maintenance of the sintering circular cooler.
出处
《武钢技术》
CAS
2015年第3期53-55,共3页
Wisco Technology
关键词
环冷机
传动装置
减速机
sintering circular cooler
transmission mechanism
reducer