摘要
目前测定水中总氮(TN)含量采用的是HJ 636—2012《水质总氮的测定碱性过硫酸钾消解紫外分光光度法》,其实验条件要求较为苛刻。用TOC/TN分析仪测定水质中总氮含量,测定样品的相对标准偏差为0.72%~4.64%,加标回收率为97.5%~103.0%,测定标准样品的相对误差为-4.33%~7.00%,精密度、准确度均能达到标准要求。该方法简化了实验步骤,提高了工作效率,可代替标准方法。
Currently,the method to determine total nitrogen(TN) content in water is environmental protection standard 'Water Quality-Determination of Total Nitrogen-Alkaline Potassium Persulfate Digestion UV Spectrophotometric Method'(HJ 636—2012)which requires extremely strict experiment conditions.By using TOC/TN analyzer to determine total nitrogen in water quality,the relative standard deviation(RSD) is 0.72%-4.64%,the recovery of standard addition is 97.5%-103.0%and the relative error is —4.33%-7.00%which means its precision,accuracy,recovery of standard addition can all meet national standard requirements.This method can simplify the experimental steps,improve working efficiency and replace the national standard method.
出处
《油气田环境保护》
CAS
2015年第3期40-42,73,共3页
Environmental Protection of Oil & Gas Fields