摘要
目的探讨角度法(TALA)评价躯干冠状面失平衡的可行性和可靠性。方法收集2013年1—12月拍摄x线脊柱全长正位片(包括骨盆)的躯干失平衡患者58例,其中男性16例,女性42例,年龄12~48岁。由A、B两位放射科医师分别独立使用躯干失平衡距离法(C7-CSVL)和TALA进行测量,间隔两周后重复测量1次。采用配对样本t检验法,分别比较两位医师每种方法的两次测量均数值,以及比较每位医师每种方法的测量均数值。结果每位医师采用C7-CSVL法的两次测量结果差异有统计学意义(P〈0.05);采用TALA法测量的两次测量结果差异无统计学意义(P〉0.05)。两位医师采用C7-CSVL法所得的测量值差异有统计学意义(P〈0.05),采用TALA法所得的测量值差异无统计学意义(P〉0.05)。结论相比较于传统的C7-CSVL法评价躯干冠状面失平衡,TALA法所得数值在不同测量者之间、同一测量者的两次测量结果差异均无统计学意义,可见TALA法评价躯干冠状面失平衡方法简单且可重复性强。
Objective To investigate the feasibility and reliability of a new method for evaluating coronal trunk imbalance, the trunk - axis - line - angle ( TALA). Methods Totally 58 patients ( 16 men and 42 women ; 12 - 48 years of age) diagnosed with trunk imbal- ance based on full - spine imaging ( including pelvis) from January 2012 to December 2013 were consecutively enrolled in this study. Two radiologists (A,B) used both the C7 - CSVL and the TALA methods respectively and independently to measure trunk imhalanee. The time interval between the two measurements was 2 weeks. A paired - sample t test examined the intraobserver and interohserver difference. Results For C7 - CSVL, there was significantly statistical difference ( P 〈 0.05 ) between the first and second measurement for each ob- server, and no statistical difference was found (P 〉 0.05) for TALA. There was statistically interobserver difference for C7 - CSVL ( P 〈 0.05 ) ,and no significantly interobserver difference was found for TALA ( P 〉 0.05 ). Conclusion Compared with C7 - CSVI., there wasn't significantly intra - and interobserver difference with TALA. Therefore, the TALA method was simple and had excellent reliability for evaluating trunk imbalanee.
出处
《医学研究杂志》
2015年第8期132-135,共4页
Journal of Medical Research
关键词
脊柱
冠状面失平衡
测量
Spine
Coronal imbalance
Measurement