目的探讨阴道炎5联检试剂(Ⅱ代)的临床应用价值。方法对1 890例妇科门诊患者的阴道分泌物同时用阴道炎5联检试剂(Ⅱ代)检测和显微镜镜检,并接种念珠菌显色平板;乳酸杆菌、细菌性阴道病(BV)以革兰染色镜检为标准,白细胞和滴虫阴道炎(TV)以湿片镜检为标准,念珠菌性外阴阴道炎(VVC)以培养结果为标准。结果阴道炎5联检试剂(Ⅱ代)与相关标准比较,乳酸杆菌、白细胞、BV、TV和VVC符合率分别为88.68%、94.81%、95.66%、99.63%和92.75%;在白细胞、BV和TV检测方面,差异均无统计学意义(P>0.05);在乳酸杆菌和VVC方面,差异有统计学意义(P<0.05)。结论阴道炎5联检试剂(Ⅱ代)操作方便,结果准确客观,在临床上便于开展,基本能够满足临床检测的需要,具有一定的临床应用价值。
Objective To explore the clinical value of vaginitis 5 combined - test diagnostic ( II ). Methods Vaginal secre- tions of 1 890 gynecological outpatients were tested with vaginitis multi tests and a microscope respectively, which were inoculated in Monilia chromogenie plates ; lactobaeillus and bacterial vaginosis (BV) were compared with Gram staining microscopic examination results, leukocyte and trichomonal vaginitis (TV) with wet microscopic examination results; candida vulvovaginitis (VVC) with culture method results. Results The coincidence rates of Lactobacillus, leukocyte, BV, TV and VVC were 88.68% , 94.81%, 95.66% , 99.63% and 92.75% , respectively, comparing this method with the related standards. On the detection results of leukocyte, BV and TV, there was no statistical significance on the difference ( P 〉 0.05 ) ; and on that of LactobaciUus and VVC, the difference had statistical significance ( P 〈 0.05 ). Conclusion The vaginitis 5 combined - test diagnostic( Ⅱ ) is simple to operate, easy to perform on the clinical and the detection results are accurate, which can meet the clinical detection needs and has certainly clinical value on application.
出处
《中国卫生检验杂志》
CAS
2015年第13期2145-2147,共3页
Chinese Journal of Health Laboratory Technology
关键词
阴道分泌物
细菌性阴道病
念珠菌
滴虫
Vaginal secretion
Bacterial vaginitis
Monilia
Trichomonal