摘要 目的检耳镜是临床诊断耳部病灶的基本工具。笔者设计了一种数字化手持式视频检耳镜。方法采用音频-视频(AV)摄像头,拍摄鼓膜、中耳或外耳道图像,实时显示在4.3吋液晶屏上,并通过AV转通用串行总线(USB)适配器,将图像传输到上位计算机上,通过上位机应用软件,实现图像的操作功能,如显示、缩放、冻结、保存等功能。并介绍了该数字化手持式视频检耳镜的机械结构、电路系统、光学成像系统。结果用数字化手持式视频检耳镜获得耳内图像。结论该视频检耳镜能改善用户体验,设计更加符合小型化、智能化和数字化。 Objective Otoscope is a basic tool for clinical diagnosis of ear diseases. The aim of this study was to design a digital handheld video otoscope. Methods AV(audio-video signal) camera was adopted to take photo of tympanic membrane, middle ear or external ear, and real-time images were displayed on 4.3-inch liquid crystal display and then transferred to the upper computer via an AV-USB adapter. The software project was installed on the upper computer, which was used to display, zoom, freeze, or save the photo. Mechanical structure, electrical system, and optical imaging system of the digital handheld otoscope were introduced. Results Image of ear from the digital handheld otoscope was acceptable. Conclusion User experience is improved, and the design is more consistent with the needs of miniaturization, intelligence and digitalization.
出处 《生物医学工程与临床》 CAS 2015年第4期350-352,共3页 Biomedical Engineering and Clinical Medicine
基金 国家级大学生创新创业训练计划(201410252045)
关键词 检耳镜 音频-视频(AV)信号 通用串行总线(USB)信号 图像显示 otoscope audio-video(AV) signal universal serial bus(USB) signal image display
  • 相关文献

参考文献8

二级参考文献26

  • 1林慧琼.小波变换在生物医学信号处理中的应用[J].国外医学(生物医学工程分册),1996,19(6):353-362. 被引量:7
  • 2赵醴,王莹,沈晓明,岳孟源,陶峥,李瑾,李璧如,许政敏.发热儿童中应常规进行耳镜检查[J].中华医学杂志,2006,86(44):3154-3155. 被引量:4
  • 3吴瑞萍 胡亚美.诸福棠实用儿科学(第6版)[M].北京:人民卫生出版社,1995.499-454.
  • 4Teele DW,Klein JO,Rosner B.Epidemiology of otitis media during the first seven years of life in children in greater Boston:a prospective,cohort study.J Infect Dis,1990,161:806-807.
  • 5Chang C,Pedler K.Ear examination-A practical guide.Aust Fam Physician,2005,34:857 -862.
  • 6Achim,A.,Bezerianos,A,and Tsakalides,P.Novel bayesian multiscale method for speckle removal in medical ultrasound images[J].IEEE trans.Med.Imag.,2001,20:772-783.
  • 7Ghofrani,S.,Jahed-Motlagh,M.R,and Ayotollahi,A.An adaptive speckle suppression filter based on Nakagami distribution[J].IEEE trans.Med.Imag.2001,1:84-87.
  • 8Quistgaard jens U.Signal acquisition and processing in medical diagnostic ultrasound[J].IEEE signal processing,1997,67-74.
  • 9Guo,H.,Odegard,M.L.,Gopinath,R.A.,Selesnick,I.W.,and Burrus,C.S.wavelet based speckle reduction with application to SAR based ATD/R[J].Proc.ICIP,1994,1:75-79.
  • 10Donolho,D.L.Denoising by soft-thresholding[J].IEEE trans.Inf.Theory,1995,41:613-627.

共引文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部