期刊文献+

振动诊断在核电厂主泵检修指导中的应用 被引量:2

The Vibration Diagnosis Application in NPP Reactor Coolant Pump Maintenance Guidance
下载PDF
导出
摘要 利用主泵振动监测系统得出的振动信号,文章结合田湾核电站俄供ΓΠH A-1391型主泵结构特点,对主泵径向止推轴承轴向振动缓慢升高的原因进行了分析,判断其上幅面板可能存在缺陷,提出了大修期间的检修建议和备件准备。在其后大修中进行检查,验证了振动分析的可靠性,为后续分析诊断提供了经验。 According to vibration signal of reactor coolant pump(RCP) vibration monitoring system and structure charactefisties of Tianwan nuclear power plant Russia ГЦ H A - 1391 type RCP, the cause of slowly rise of the RCP radial thrust bearing axial vibration is analyzed, and conclusion that upper panel may be flawed is drawn. Suggestions and preparations of spare parts are put forward to the overhaul maintenance. The reliability of vibration analysis is verified, and which provides the experience for subsequent analysis.
出处 《中国核电》 2015年第2期142-146,共5页 China Nuclear Power
关键词 主泵 振动 检修 reactor coolant pump vibmtion maintenance
  • 相关文献

参考文献3

二级参考文献8

  • 1王冶,硕士学位论文,1997年
  • 2周耀华,数字信号处理,1992年,20页
  • 3屈梁生,机械故障诊断学,1986年,6-18,47-56,81-91页
  • 4周慧辉.主泵径向止推轴承水力计算[R].
  • 5曾小康.2JEB30FT901下降原因分析报告[R].
  • 6尼基夫洛夫.俄罗斯基洛夫主泵厂关于江苏核电有限公司《除盐水供应系统(KBC2)压力引入到主泵头箱方案可行性评价》的回函[R].
  • 7赵振宇,高培.岭澳核电站主泵动平衡[J].中国设备工程,2011(4):32-34. 被引量:9
  • 8吕群贤.反应堆主泵现场动平衡[J].核动力工程,2002,23(3):63-68. 被引量:8