本文较为详细地阐述了在地下室顶板中采用有粘结预应力无梁楼盖的设计和施工,包括荷载的取值、内力的计算,抗弯、裂缝及冲切的验算,以及一些复杂情况的处理和构造措施等,使得这个地下室顶板工程的设计施工安全、经济、合理。
The design and construction of bonded prestressed floor without beam applied in the basement roof are explained in detail in this article,including the value of the load,the calculation of internal forces,checking of bending,punching and cracks,as well as the processing of some complex situations and structural measures,which would make the design and construction of basement roof safety,economy,and reasonable.
出处
《福建建筑》
2015年第7期78-80,共3页
Fujian Architecture & Construction
关键词
有粘结预应力
无梁楼盖
设计
施工
Bonded prestressed
Floor without beam
Design
Construction