MSCT后处理技术在骨关节损伤中的应用 被引量:4

Application of MSCT Postprocessing Technique in Trauma of Bones and Joints
下载PDF
导出
摘要 目的:探讨多层螺旋CT(MSCT)及多平面重建(MPR)、VR成像(3D)后处理功能在骨关节损伤诊断中的价值。方法:113例骨关节损伤患者行MSCT螺旋扫描后采用MPR和VR后处理并与平片进行比较。结果:MSCT横断位可发现细微骨折,MPR、VR能准确显示骨关节损伤部位、类型、严重程度、骨折和脱位的空间位置关系,MPR能显示软组织损伤情况。结论:MSCT横断位结合MPR、VR可提高骨关节损伤诊断准确性,为临床诊治提供更多帮助。 Objective To discuss the diagnostic of MSCT with MPR and VR post-imaging processing technique on trauma of bones and joints. Methods 113 patients with fracture or dislocation, were checked with axial images of MSCT with MPR and VR images. The results were compared with X-ray plain film. Results Axial images of MSCT could show tiny fracture, MPR and VR accurately revealed the trauma of bones and joints location, type,severity,displaying space relationship of fracture and dislocation. MPR could show the trauma of soft tissue. Conclusion Axial imaging MSCT, combined with MPR and VR postprocessing technique can increase the diagnostic accuracy, give more help to clinical treatment.
作者 龙平秋
出处 《深圳中西医结合杂志》 2015年第10期89-90,F0003,共3页 Shenzhen Journal of Integrated Traditional Chinese and Western Medicine
关键词 骨关节损伤 X线片 多层螺旋CT 图像后处理 Bone and joint trauma X-ray MSCT Imaging postprocessing
  • 相关文献

参考文献8

二级参考文献39

  • 1秦瑞峰,封兴华,胡开进.螺旋CT三维成像在颌面部复杂骨折中的应用[J].实用放射学杂志,2004,20(10):881-882. 被引量:30
  • 2廉宗,韩悦,陈万青.隐匿性骨内骨折的MRI诊断一例[J].中华放射学杂志,1994,28(2):140-140. 被引量:10
  • 3刘昌杰,徐睿,王楠竹,王涛.多层螺旋CT图像后处理技术在骨关节创伤中的应用价值[J].中国现代医学杂志,2006,16(3):447-448. 被引量:10
  • 4吴春江,蒋学祥,李松年,高玉洁.膝关节交叉韧带及其损伤的MRI诊断[J].中华放射学杂志,1996,30(8):545-548. 被引量:13
  • 5HAVERI M, JUNILA J, SURAMO I, et al. Multiplanar and 3D CT of acetabular fractures[J]. Acta Radiol, 1998, 39(3): 257-264.
  • 6KASALES CJ,MAUGER DT,SEFEGEK RJ,et al. Multipanar image reconstruction and 3D imaging using a musculoskeletal phantom:Conventional versus helical CT[J]. J comput Assist Tomogr, 1997, 21(1): 162-169.
  • 7BROWN GA, WILLIS MC, F1ROOZBAKHSH K, et al. Computed tomography image-guided surgery in complex acetabular fractures[J]. Clin orthop, 2000, 370(1): 219-220.
  • 8HOWARD JD, ELSTER AD, MAY JS. Temporal bone: three-dimensional CT. Part Ⅱ. Pathalogic alteration[J]. Radialogy, 1990,177(3): 427-430.
  • 9Eustace S, Keogh C, Blake M, et al. MR Imaging of bone oedema : mechanisms and interpretation. Clinical Radiology ,2001 ,56( 1 ) : 4.
  • 10Memarsadeghi M, Breitenseher MJ, Prokop CS, et al. Occult Scaphoid factures : comparison of muhidetector CT and MR imaging-initial experience. Radiology, 2006, 240(1): 169.

共引文献69

同被引文献24

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部