期刊文献+

2×35t/h循环流化床锅炉防磨技改

Anti Abrasives Measures on 35 t/h CFB Boiler
原文传递
导出
摘要 在2×35 t/h循环流化床锅炉运行过程中,风帽、埋管和旋风分离器顶部等部位发生严重磨损问题。在锅炉改造中,对风帽进行了调平,对埋管加装了防磨措施,并对旋风分离器顶部易发生磨损的部位辐射了耐火浇注料。并在运行过程中严格控制空气过剩系数在1.3以下。运行结果表明,锅炉的磨损问题得到大幅度缓解,在一年的运行过程中没有发生锅炉的非停。 In the operation of the 2 × 35 t/h circulating fluidized bed boiler, there were serious erosion on the air nozzles, immersed tubes and the flue gas exit area of the cyclones. In the boiler retrofits, anti abrasive measures and refractory linings were added to the immersed tubes and the exit area After the boiler retrofits, the above problems become much the past year's operation. of the cyclone, respective, as well as the air caps leveling. more relieved and the there was no unplanned downtime in
出处 《电站系统工程》 2015年第4期81-82,共2页 Power System Engineering
关键词 循环流化床锅炉 磨损 技改 CFB boiler erosion retrofits
  • 相关文献

参考文献2

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部