期刊文献+

微创L5椎弓根钉进钉点的有效性分析 被引量:1

Effectiveness of L_5 pedicle screw insertion with a minimally invasive method
下载PDF
导出
摘要 背景:在临床应用中,第5腰椎人字嵴结构不清,往往需扩大显露范围,通过横突、上下关节突等结构明确进钉点,增加了创伤和医源性上位椎间退变的风险。因此有必明确一个微创的L5椎弓根钉进钉点。目的:通过影像学评价以L5乳突"斜坡"作为进钉点的L5椎弓根螺钉置入准确性。方法:第5腰椎上关节突基底部的乳突向后突起的最高点向内下方延伸过程中形成一斜面,将其定义为乳突"斜坡";其内侧为椎弓根部内上缘,向外比邻横突根部,位于人字嵴结构顶点的略上方,"斜坡"是椎旁肌间隙入路时可最先触及且显露的骨性部位。以乳突"斜坡"为进钉点,对50例腰椎退行性疾病患者行L5椎弓根螺钉置入内固定,根据术前CT和X射线透视确定椎弓根钉矢状面和横断面的进钉方向。椎弓根钉直径均为6.5 mm。修复过程中评价其一次性置钉成功率,置钉后行腰椎正侧位X射线片和CT检查,评价置钉准确率。结果与结论:应用乳突"斜坡"定位法的一次性置钉成功率为96%(96/100);于L5椎体内共置入100枚椎弓根螺钉,根据Gertzbein等推荐的标准,95枚(95%)螺钉完全位于椎弓根内,5枚(5%)螺钉均向内侧穿透椎弓根皮质,其中3枚(3%)螺钉穿透距离<2 mm,2枚(2%)螺钉穿透距离为2-4 mm,均未出现神经根损伤等并发症。提示L5乳突"斜坡"定位法的一次性置钉成功率高,结合置钉前的X射线片和CT评价可获得较高的置钉准确率。 BACKGROUND:In clinical application,the structure of crista lambdoidalis of L5 was unclear.It needs to expose more tissue to define L5 entry point through transverse process or superior and inferior articular process.This increased the risk of trauma and iatrogenic superior intervertebral degeneration.Therefore,it is necessary to expose L5 entry point with a minimally invasive way.OBJECTIVE:To investigate the accuracy of L5 pedicle screw insertion with the entry point of mastoid process slope by imaging.METHODS:Mastoid process was located on the base of L5 superior articular process.A cant was formed when the highest point of L5 mastoid process backward protuberance extended inwards and downwards.The cant was defined as mastoid process slope; it was lateral to pedicle medial superior side internally,medial to transverse process root and superior to the top of crista lambdoidalis.The slope was first easily touched and exposed in lumbar posterior surgery through paraspinal muscle space approach.Fifty patients of lumbar spine disorders were treated by L5 pedicle screws fixation through the entry point of mastoid process slope.According to preoperative radiographic and CT images,pedicle screw insertion direction of the sagittal and transverse sectionswas calculated.The diameter of pedicle screw was 6.5 mm.The condition of intraoperative successful rate of screws placement at one time was analyzed.The accuracy of screw placement was evaluated by postoperative radiographic and CT images.RESULTS AND CONCLUSION:With the method of the mastoid process slope,the successful rate of screw placement at one time was 96%(96/100).Totally 100 screws were inserted into L5.According to the criterion by Gertzbein,95screws(95%) totally located in pedicles and 5 screws(5%) encroached on the pedicle from medial wall.Three(3%) out of 5 inaccurately placed screws cut out less than 2 mm of the inner wall,while 2(2%) between 2 mm and 4 mm,without neurologic deficits.The method of mastoid process slope had a high successful rate of screw placement.Combined with preoperative X-ray films and CT images could obtain a high accuracy rate of screw insertion.
出处 《中国组织工程研究》 CAS 北大核心 2015年第26期4180-4185,共6页 Chinese Journal of Tissue Engineering Research
关键词 植入物 脊柱植入物 椎弓根螺钉 内固定 进钉点 置钉准确性 Lumbar Vertebrae Bone Nails Internal Fixators
  • 相关文献

参考文献40

  • 1Roy-Camille R, Saillant G, Mazel C. Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. 1986; (203):7-17.
  • 2Boos N, Webb JK. Pedicle screw fixation in spinal disorders: a European view. Eur Spine J. 1997; 6(1):2-18.
  • 3Pihlajamaki H, Myllynen P, Bostman O. Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br. 1997; 79:183-189.
  • 4Jutte PC, Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J. 2002; 11:594-598.
  • 5Davne SH, Myers DL. Complications of lumbar spinal fusion with transpedicular instrumentation. Spine. 1992; 17:S184- S189.
  • 6Blumenthal S, Gill K. Complications of the Wiltse pedicle screw fixation systems. Spine. 1993; 18:1867-1871.
  • 7Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. Spine. 1993;18: 2231-2239.
  • 8Hou S, Hu R, Shi Y. Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population. Spine. 1993; 18(13): 1850-1855.
  • 9Ebraheim NA, Xu R, Darwich M, et al. Anatomic relations between the lumbar pedicle and adjacent neural structures. Spine. 1997; 22(20):2338-2341.
  • 10Mitra SR, Datir SP, Jadhav SO. Morphometric study of the lumbar pedicle in the Indian population as related to pedicular screw fixation. Spine. 2002; 27(5):453-459.

二级参考文献47

共引文献258

同被引文献12

  • 1Krag MH, Van Hal ME, Beynnon BD. Placement of transpedicular vertebral screws close to anterior vertebral cortex. Description of methods [J]. Spine, 1989, 14(8): 879-883.
  • 2Magerl FP. Stabilization of the lower thoracic and lumbar spine with external skeletal fixation [J]. Clin Orthop Relat Res, 1984, 189: 125- 141.
  • 3Weinstein JN, Spratt KF, Spengler D, et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement [J]. Spine, 1988, 13(9): 1012- 1018.
  • 4Heary RF, Bono CM, Black M. Thoracic pediele screws: postoperative computerized tomography scanning assessment [J]. J Neurosurgery, 2004, 100(4 Suppl Spine): 325-331.
  • 5Ebraheim NA, Rollins JR Jr, Xu R, et al. Projection of the lumbar pedicle and its morphometrie analysis [J]. Spine, 1996, 21(11): 1296- 1300.
  • 6Ebraheim NA, Xu R, Ahmad M, et al. Projection of the thoracic pedicle and its morphometric analysis [J]. Spine, 1997, 22(3): 233-238.
  • 7Tsubota K, Suzuki Y, Yamada T, et al. Computer simulation of tmbecular remodeling in human proximal femur using large-scale voxel FE models: Approach to understanding Wolffs law [J]. J Biomech, 2009, 42(8): 1088-1094.
  • 8Yuan Q, Han X, Han X, et al. Krag versus Caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis [J]. Spine, 2014, 39(26 Spec No.): B27-B35.
  • 9Schmidt H, Heuer F, Claes L, et al. The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis [J]. Clin Biomech (Bristol, Avon), 2008, 23(3): 270-278.
  • 10Zeng ZL, Jia L, Xu W, et al. Analysis of risk factors for adjacent superior vertebral pedicle- induced facet joint violation during the minimally invasive surgery transforaminal lumbar interbody fusion: a retrospective study [J]. Eur J Med Res, 2015, 20(1): 80.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部