摘要 在乳腺专用CT(DBCT)系统中,图像质量和人体所受辐射剂量是倍受关注的两个重要因素。本文采用蒙特卡罗模拟方法研究球管电压和滤片对图像质量和剂量的影响,并引入与图像分辨率、噪声、辐射剂量相关的剂量效率η,综合评估辐射剂量和图像质量的关系。研究结果表明:选择合理的管电压值能够获得较好的剂量效率,并且通过优化滤片的形状可以在保证图像质量的同时降低人体所受剂量,为乳腺专用CT的临床应用提供重要参考。 The image quality and the radiation dose are important performance indicator of dedicated breast CT(DBCT). In this paper, the factors of tube voltage and filter were studied by Monte Carlo simulation method which have effect on the image quality and radiation dose which for comprehensive assessing the relationship between them that introduced the dose efficiency η that related to image resolution, noise and radiation dose. Research results show favorable dose efficiency can be gained if reasonable voltage values are selected and that optimization of filter shape can reduce dosage which human body absorbs. Therefore, rational setting of parameters can decrease radiation dose and provide significant reference for clinical application of dedicated breast CT while guaranteeing image quality as far as possible.
出处 《CT理论与应用研究(中英文)》 2015年第3期327-336,共10页 Computerized Tomography Theory and Applications
基金 国家自然青年科学基金(81301225 81101045) 中国科学院高能物理研究所科研基金(2013IHEPYJRC801)
关键词 乳腺专用CT 滤片 GATE模拟 辐射剂量 图像质量 dedicated breast CT filter GATE radiation dose image quality
  • 相关文献

参考文献14

  • 1郑莹,吴春晓,吴凡.中国女性乳腺癌死亡现况和发展趋势[J].中华预防医学杂志,2011,45(2):150-154. 被引量:180
  • 2赵平,陈万青,孔灵芝.中国癌症发病与死亡(2003-2007)[M].北京:军事医学科学出版社,2011:91-94.
  • 3Lai CJ, Shaw CC, Chen LY, et al. Visibility of micro calcification in CBBCT-Effects of X-ray tube voltage and radiation dose[J]. Medical Physics, 2007, 34(7): 2995 3004.
  • 4Chen B, Ning R. Cone-beam volume CT breast imaging: Feasibility study[J]. Medical Physics 2002, 29 (5): 755-770.
  • 5GlickSJ, VedantbamS, KarellasA. Investigation of optimalkVpsettingforCTmammography using a flat-panel imager[J]. Proceedings of the International Society for Optical Engineeringl 2001, 4682: 392-402.
  • 6XiaoT, Wei Z, Yan-FangW, et al. Monte carlo simulation of glandular dose inadedicated breast CT system[J]. Chinese Physical Society(C), 2012, 36(7): 675-680.
  • 7Ferlay J, Shin HR, Bray F, et al. Olobocan 2008, cancer incidence and mortality world wide: IARC CancerBase NO. 10[C]//Lyon, International Agency for Research on Cancer, 2010.
  • 8Mittone A, Bravin A, Coan P. Radiation dose in breast CT imaging with monochromatic X-rays Simulation study of the infl.
  • 9uence of energy, composition and thickness[J]. Physics in Medicine and Biology, 2014, 59(9): 2199-2217.
  • 10Boone JM, Nelson TR, Lindfors KK, et al. quality evaluationl[J]. Radiology, 2001, Dedicated breast CT: Radiation dose and image 221(3): 657-667.