前瞻性心电门控技术80kV-CT冠脉造影的临床应用研究 被引量:3

Clinical Research of 80 kV-CT Coronary Angiography for Prospectively Gated Axial Technique
下载PDF
导出
摘要 目的:评价80 k V-CT冠脉造影图像质量与辐射剂量,明确其临床应用价值。方法:选取拟行CT冠状动脉造影的患者61例,随机分为两组。A组管电压设置为80 k V,管电流300--450 m A;B组管电压设置为120 k V,管电流200--350 m A。比较A和B两组的主观图像质量、客观图像质量(CT值、噪声值、SNR、CNR)及辐射剂量。P〈0.05认为差异有统计学意义。结果:A组平均得分3.36±0.68,B组平均得分4.58±0.67,A组与B组(t=-25.859,P=0.000)差异有统计学意义。A组可评估率为97.32%,B组可评估率为99.02%,A组与B组(χ2=3.276,P=0.070)差异无统计学意义。主动脉根部CT值,A组为(573.11±150.42)HU,B组为(428.41±95.32)HU,A组与B组(t=4.434,P=0.000)差异具有统计学意义;主动脉根部噪声值,A组为(43.32±12.25)HU,B组为(28.79±7.61)HU,A组与B组(t=5.488,P=0.000)差异具有统计学意义;主动脉根部SNR,A组为13.99±4.80,B组为14.78±3.50,A组与B组(t=-0.725,P=0.471)差异无统计学意义;主动脉根部CNR,A组为16.25±5.18,B组为18.82±4.65,A组与B组(t=-2.031,P=0.047)差异具有统计学意义;A组ED为(0.95±0.09)m Sv,B组ED为(2.07±0.21)m Sv,A组与B组(t=-28.052,P=0.000)差异有统计学意义。结论:通过适当提高管电流的80 k V-CTCA可以大幅减低辐射剂量,而图像质量可满足诊断。 Objective: To evaluate image quality and radiation dose for coronary artery computed tomographic angiography(CTA) obtained with 80 k V. Methods: 61 patients enrolled in this study were randomly divided into two groups. The group A was 32 patients with tube voltage 80 k V and tube current(200-350)m A. The group B was 29 patients with tube voltage 120 k V and tube current(300-450)m A. Two groups were evaluated for the image quality score, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in aortic root and radiation dose. The image quality and radiation dose was compared by Chi-square test and unpaired t-test. A P value below 0.05 was considered to be statistically significant. Results: The aortic root showed significantly higher mean image quality score, mean attenuation, noise and CNR in group A than in group B(P = 0.000, P = 0.000, P = 0.000, P = 0.047, respectively). The SNR was not statistically significant for group A versus group B(P = 0.471). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 3.276, P = 0.070). The mean effective dose was statistically significant for the group A was 0.95 m Sv versus 2.07 m Sv for the group B(t =-28.052, P = 0.000). Conclusion: 80 k V-CTCA with higher tube current could offer assessable image quality and substantially reduced effective radiation dose.
作者 包丽薇
出处 《CT理论与应用研究(中英文)》 2015年第3期401-408,共8页 Computerized Tomography Theory and Applications
基金 内蒙古医科大学青年创新基金(YKD2013QNCX024)
关键词 体层摄影术 X线计算机 冠状动脉 图像质量 辐射剂量 tomography X-ray computed coronary artery image quality radiation dose
  • 相关文献

参考文献16

  • 1Maffei E, Martini C, De Crescenzo S, et al. Low dose CT of the heart: A quantum leap into a new era of cardiovascular imaging[J]. Radiology Medical, 2010, 115: 1179-1207.
  • 2Sung WK, Young JK, Jaemin S, et al. Coronary artery calcium scoring does not add prognostic va]ue to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease[J]. Radiology. 259: 92-99.
  • 3王妍焱,吴国庚,周诚,高建华,焦晟,曹会志.64层螺旋CT前门控冠状动脉横断面扫描低剂量技术的初步研究[J].中华放射学杂志,2008,42(10):1018-1021. 被引量:79
  • 4Earls JP, Berman EL, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose[J]. Radiology, 2008, 246: 742-753.
  • 5马延贺,于铁链,李东,李锋坦.64层螺旋CT冠状动脉成像中前瞻性心电门控技术的应用价值[J].中国医学影像技术,2010,26(3):492-495. 被引量:21
  • 6Engel L, Ferencik M, Liew GY, et al. Ultra-low dose cardiac CT angiography at 80 kV using second generation dual-source CT: Assessment of radiation dose and image quality[J]. Journal of Medical Diagnosis Method, 2012, 1: 1-7.
  • 7Komatsu S, Kamata T, Imai A, et al. Coronary computed tomography angiography using ultra-low-dose contrast media: Radiation dose and image quality[J]. International Journal of Cardiovascular Imaging, 2012, 59(13sl): E1357-E1357.
  • 8Guidelines on Radiation Dose to the Patient[RJ. European Commission. guropean gulaellnes on quality criteria for computed tomography. Report EUR 16262 EN. Office for Official Publication of the European Communities, Luxembourg. http://www, drs. dk/guidelines /ct/quality/index. htm. Accessed 20 January 2010.
  • 9Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: Report of the ad hoc committee for grading of coronary artery discase, council on cardiovascular surgery, american heart association[J]. Circulation, 1975, 51($4): 5-40.
  • 10ICRP Publication 60:1990 recommendations of the international commission on radiological protectionEM]. Annals of the ICRP 21(1-3). Oxford: Pergamon Press, 1991.

二级参考文献31

  • 1张森,杜湘珂,李剑颖.心电图调制电流对于容积CT心脏扫描图像质量及曝光剂量影响的评估[J].中华放射学杂志,2006,40(9):974-976. 被引量:45
  • 2Trabold T, Buchgeister M, Kuttner A, et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo, 2003, 175 : 1051-1055.
  • 3Mallet NR, Cademartiri F, van Mieghem CA, et al. High- resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation, 2005,112 : 2318-2323.
  • 4Flohr TG, Schoepf U J, Kuettner A, et al. Advances in cardiac imaging with 16-section CT systems. Acad Radiol, 2003, 10: 386-401.
  • 5Hsieh J, Londt J, Vass M, et al. Step-and-shoot data acquisition and reconstruction for cardiac X-ray computed tomography. Med Phys, 2006,33:4236-4248.
  • 6Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology,2003,226 : 145-152.
  • 7Trabold T, Buchgeister M, Kuttner A, et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo, 2003, 175: 1051-1055.
  • 8Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Call Cardiol, 2004, 43 : 1241-1247.
  • 9Leber AW, Becker A, Knez A, et al. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary, system : a comparative study using intravascular ultrasound. J Am Coil Cardiol, 2006, 47:672-677.
  • 10Mnllet NR, Cademartiri F, van Mieghem CA, et al. High- resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.Circulation, 2005, 112:2318-2323.

共引文献139

同被引文献28

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部