通过对某一工业X射线探伤室实例进行辐射屏蔽理论计算,并与实际工作中的辐射剂量率水平现场检测数据进行对比,分析理论计算结果与实际检测数据的差异,探讨理论计算方法应用于X射线探伤室设计或评价的可行性。
According to the radiation shielding theoretical calculation of an industrial X-ray detection chamber, and comparing with the field test data of the radiation dose rate, differences are analyzed between theoretical calculation value and the measured data, the feasibility of the theoretical calculation method is explored in the design and evaluation of X-ray detection chamber.
出处
《广东化工》
CAS
2015年第14期59-60,48,共3页
Guangdong Chemical Industry
关键词
工业X射线探伤
辐射屏蔽效果
理论计算
现场实测
industrial X-ray detection chamber
radiation shielding effective
theoretical calculation