摘要
以某建筑防雷接地安装为例,分析了提前放电避雷针选型和在网架、金属幕墙上安装过程中遇到的问题,说明了同时使用金属幕墙、玻璃幕墙和石材幕墙时防雷施工技术措施的要点。
This paper in a lightning protection grounding and installation as an example, analyzes the early selection of the discharge of lightning rod and the problems encountered in the process of installation on the rack, metal curtain wall, illustrates the simultaneous use of metal curtain wall, glass curtain wall and stone curtain wall the technical measures for lightning protection construction points.
出处
《科技与创新》
2015年第16期146-147,共2页
Science and Technology & Innovation
关键词
高层建筑
防雷接地
安装技术
接闪器
high-rise building
lightning protection grounding
installation technology
air terminals