期刊文献+

Sparse current source reconstruction in MCG

Sparse current source reconstruction in MCG
原文传递
导出
摘要 Cardiac current source reconstruction is investigated by a fast greedy sparse(FGS) method applied to simulated and real magnetocardiography(MCG) data measured using 61-channel superconducting quantum interference device. The approach reduces the size of the lead field matrix based on a priori knowledge of dipolar magnetic field map. Consequently, the computational demands and the accuracy of sparse source reconstruction are improved simultaneously. The simulation results demonstrate that the FGS method is capable of reconstructing sparse equivalent current sources using the magnetic field data generated by a single current source with varying orientation or multiple current sources generated randomly. In addition, we analyze the cardiac current source reconstructed with real MCG data at typical instants and discuss the electrical excitation conduction during the QRS complex based on moving sparse source imaging. Cardiac current source reconstruction is investigated by a fast greedy sparse (FGS) method applied to simulated and real magnetocardiography (MCG) data measured using 61-channel superconducting quantum interference device. The approach reduces the size of the lead field matrix based on a priori knowledge of dipolar magnetic field map. Consequently, the computational demands and the accuracy of sparse source reconstruction are improved simultaneously. The simulation results demonstrate that the FGS method is capable of recon- structing sparse equivalent current sources using the magnetic field data generated by a single current source with varying orientation or multiple current sources generated randomly. In addition, we analyze the cardiac current source reconstructed with real MCG data at typical instants and discuss the electrical excitation conduction during the QRS complex based on moving sparse source imaging.
出处 《Science Bulletin》 SCIE EI CAS CSCD 2015年第14期1235-1240,共6页 科学通报(英文版)
基金 supported by the National Natural Science Foundation of China(60771030) the National HighTechnology Research and Development Program of China(2008AA02Z308) the Shanghai Science and Technology Development Foundation(08JC1421800) Shanghai Leading Academic Discipline Project(B004) the Open Project of State Key Laboratory of Function Materials for Information(Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences)
关键词 稀疏流 超导量子干涉器件 计算精度 电流源 先验知识 仿真结果 GS方法 随机生成 Magnetocardiography (MCG) Sparsedecomposition Current source reconstruction Cardiac electrical activity Signal processing
  • 相关文献

参考文献1

二级参考文献21

  • 1He B 2003 Modeling and Imaging of Bioelectrical Activity: Principles and applications (Minn.
  • 2Gutierrez D, Nehorai A, Dogandzic A 2006 IEEE Transactions on Biomedical Engineering 53 840.
  • 3Moiseev A, Gaspar J M, Schneider J A, Herdman A T 2011 Neuroimage 58 481.
  • 4Gorodnitsky I F, George J S, Rao B D 1995 Electroencephalography and clinical Neurophysiolo.
  • 5Melis M D, Tanaka K, Uchikawa Y 2010 IEEE Transactions on magnetics 38 1203.
  • 6Michel C M, Murray M 2004 Clinical Neurophysiology 115 2195.
  • 7Davis G 1994 Ph. D. Dissertation (U.S.A: New York University).
  • 8Chen S S, Donoho D L, Saunders M A 1998 SIAM Journal of Scientific Computing 20 33.
  • 9Liu H S, Schimpf P H, Dong G Y, Gao X R, Yang F S, Gao S K 2005 IEEE Transactions on Biomed.
  • 10Xu P, Tian Y, Chen H F, Yao D Z 2007 IEEE Transactions on Biomedical Engineering 54 400.