配置抗剪栓钉的钢筋混凝土单向板柱节点受剪性能试验研究 被引量:6

Experimental study on shear performance of reinforced concrete one-way slab-column connection with shear studs
原文传递
导出
摘要 为了研究抗剪栓钉对板的破坏形态和受剪切性能的影响,完成了3组6个设有抗剪栓钉的钢筋混凝土单向板柱节点受剪试验。在3组试件中,第1组为未配置抗剪栓钉的具有不同剪跨比的钢筋混凝土单向板试件,其他两组为配置有不同间距和高度的抗剪栓钉的对比试件,研究的主要参数为抗剪栓钉的间距、高度和板的剪跨比。研究结果表明:同未配置抗剪栓钉的钢筋混凝土单向板柱节点发生剪切破坏的情况相比,配置抗剪栓钉的钢筋混凝土单向板柱节点分别发生了栓钉群内(S50-5系列试件)和群外(S50-7系列试件)的剪切破坏;使用抗剪栓钉能有效提高板柱节点的延性,改善失效模式,使单纯的剪切破坏向弯曲破坏转变,与抗剪栓钉相交的斜裂缝更为平缓,从而使受剪承载力明显提高;配置抗剪栓钉对钢筋混凝土单向板柱节点的加强效果随着抗剪栓钉间距和高度的改变存在较大差别,特别是对剪跨比较小的钢筋混凝土单向板影响更为显著。基于试验结果,给出了不同剪跨比的钢筋混凝土单向板与柱栓钉连接的设计建议。 Failure modes and the influences on shear performance are researched based on three groups of six reinforced concrete one-way slab-column connection test with stud strengthening. One group is different shear span ratios reinforced concrete one-way slab without shear studs,the other two groups are contrast specimens with different spacing and shear stud's length. The main parameters are the spacing of shear studs,the height of shear studs and shear span ratio. Test results show that compared to the reinforced concrete one-way slab-column connection,the shear failure,failure modes of connections with shear studs are inside( S50-5 series specimens) and outside( S50-7 series specimens) shear studs. Using shear studs can improve effectively ductility of the slab-column connection,and change the failure mode from the pure shear failure to bending failure. The inclined destruction cracks located in the intersection with shear studs are more gently. From what has been discussed above the ultimate shear bearing capacity is improved obviously. Reinforcement effect is different because of the change of stud spacing and stud length,which is more significant to the relatively small shear span ratio reinforced concrete one-way slab. Based on the test results design suggestions are given to reinforced concrete plate with different shear span ratios.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2015年第8期66-72,共7页 Journal of Building Structures
基金 国家自然科学基金重点项目(51338004) 浙江省自然科学基金项目(LY12E08013)
关键词 钢筋混凝土 单向板柱节点 抗剪栓钉 栓钉加固 静载试验 延性 受剪承载力 reinforced concrete one-way slab-column connection shear stud stud strengthening static test ductility shear bearing capacity
  • 相关文献

参考文献12

  • 1CSA A23.3-04 Design of concrete structures [ S ]. Ontario: Canadian Standards Association ,2004:77-96.
  • 2Ghali A. An efficient solution to punching of slabs [ J ].Concrete International, 1989, 102 (2) : 50-54.
  • 3ACI 318438 Building code requirements for structural concrete and commentary [ S ]. Farmington Hills, Michigan : American Concrete Institute ,2008:470-473.
  • 4Guans H, Loo Y C. Failure analysis of column-slab connections with stud shear reinforcement [ J ]. Canadian Journal of Civil Engineering, 2003,30 ( 6 ) : 934-944.
  • 5Cho Y S, Noh S Y, Kim H W. Punching shear reinforcing using shear studs with steel plates in reinforced concrete fiat plates [ J 1- Magazine of Concrete Research, 2009, 61 (9) :721-729.
  • 6GB50010-2010,混凝土结构设计规范[s].北京:中国建筑工业出版社.2010.
  • 7舒兆发,李定国.配置抗冲切钢筋的混凝土板柱连接的强度和性能试验研究[J].湖南大学学报,1987,14(1):39-52.
  • 8楼板及基础冲切强度专题组.钢筋混凝土板和基础冲切强度的试验研究.建筑结构学报,1987,.
  • 9周朝阳.配置抗冲切钢筋的混凝土板柱连接的破坏形态与承载力分析[J].建筑结构学报,1997,18(6):26-31. 被引量:13
  • 10Ghali A, Youakim S A. Headed shear studs in concrete: state of the art[J]. ACI Structural Journal, 2005, 102 (5) :657-667.

二级参考文献3

  • 1周朝阳,结构工程学报,1991年,3/4期
  • 2周朝阳,博士学位论文,1989年
  • 3舒兆发,湖南大学学报,1987年,1期

共引文献419

同被引文献41

引证文献6

二级引证文献21