期刊文献+

Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging 被引量:5

Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
下载PDF
导出
摘要 AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was performed on Pub Med, MEDLINE and EMBASE up to August 2014. Nine studies(10 sets of data) with a total of 304 malignant pancreatic lesions and 188 benign pancreatic lesions were included. The characteristics of each study included the study name, year of publication, magnetic resonance modalities used, patient population, strength of field, pulse time, repetition time, echo time(TE), maximum b factor, mean age, mean body weight, fat suppression, number of benign and malignant lesions, and true positive, true negative, false positive and false negative results. All analyses were performed using Meta-Di Sc and Stata 11.0.RESULTS: The pooled sensitivity and specificity of singleshot EPI DWI were 0.83(95%CI: 0.79-0.87) and 0.77(95%CI: 0.70-0.83), respectively. The positive likelihood ratio and negative likelihood ratio were 5.09(95%CI: 2.19-11.84) and 0.23(95%CI: 0.15-0.36), respectively. The P value for the χ2 heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.89 and 0.82, respectively. Publication bias was not present(t = 0.58, P = 0.58). Meta-regression analysis indicated that fat suppression, mean age, TE, and maximum b factor were not sources of heterogeneity(all P > 0.05). CONCLUSION: Single-shot EPI DWI is useful to differentiate between malignant and benign pancreatic lesions. Lesion size ≥ 2 cm is the limit for the diagnosis of early lesions. AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was performed on Pub Med, MEDLINE and EMBASE up to August 2014. Nine studies(10 sets of data) with a total of 304 malignant pancreatic lesions and 188 benign pancreatic lesions were included. The characteristics of each study included the study name, year of publication, magnetic resonance modalities used, patient population, strength of field, pulse time, repetition time, echo time(TE), maximum b factor, mean age, mean body weight, fat suppression, number of benign and malignant lesions, and true positive, true negative, false positive and false negative results. All analyses were performed using Meta-Di Sc and Stata 11.0.RESULTS: The pooled sensitivity and specificity of singleshot EPI DWI were 0.83(95%CI: 0.79-0.87) and 0.77(95%CI: 0.70-0.83), respectively. The positive likelihood ratio and negative likelihood ratio were 5.09(95%CI: 2.19-11.84) and 0.23(95%CI: 0.15-0.36), respectively. The P value for the χ2 heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.89 and 0.82, respectively. Publication bias was not present(t = 0.58, P = 0.58). Meta-regression analysis indicated that fat suppression, mean age, TE, and maximum b factor were not sources of heterogeneity(all P > 0.05). CONCLUSION: Single-shot EPI DWI is useful to differentiate between malignant and benign pancreatic lesions. Lesion size ≥ 2 cm is the limit for the diagnosis of early lesions.
出处 《World Journal of Gastroenterology》 SCIE CAS 2015年第20期6374-6380,共7页 世界胃肠病学杂志(英文版)
基金 Supported by Key Program of Scientific Research of Fujian Medical University,FMU 09ZD014
关键词 Meta-analysis Single-shot echo-planarimaging DIFFUSION-WEIGHTED imaging PANCREATIC cancer Differential diagnosis Meta-analysis Single-shot echo-planar imaging Diffusion-weighted imaging Pancreatic cancer Differential diagnosis
  • 相关文献

参考文献32

  • 1Balachandran A, Bhosale PR, Charnsangavej C, Tamm EP.Imaging of pancreatic neoplasms. Surg Oncol Clin N Am 2014; 23:751-788 [PMID: 25246049 DOI: 10.1016/j.soc.2014.07.002].
  • 2Ichikawa T, Erturk SM, Motosugi U, Sou H, Iino H, Araki T, FujiiH. High-b value diffusion-weighted MRI for detecting pancreaticadenocarcinoma: preliminary results. AJR Am J Roentgenol 2007;188: 409-414 [PMID: 17242249 DOI: 10.2214/AJR.05.1918].
  • 3Tamm EP, Bhosale PR, Vikram R, de Almeida Marcal LP,Balachandran A. Imaging of pancreatic ductal adenocarcinoma:State of the art. World J Radiol 2013; 5: 98-105 [PMID: 23671746DOI: 10.4329/wjr.v5.i3.98].
  • 4Taniguchi T, Kobayashi H, Nishikawa K, Iida E, Michigami Y,Morimoto E, Yamashita R, Miyagi K, Okamoto M. Diffusionweightedmagnetic resonance imaging in autoimmune pancreatitis.Jpn J Radiol 2009; 27: 138-142 [PMID: 19412681 DOI: 10.1007/s11604-008-0311-2].
  • 5Wang Y, Chen ZE, Nikolaidis P, McCarthy RJ, Merrick L, SternickLA, Horowitz JM, Yaghmai V, Miller FH. Diffusion-weightedmagnetic resonance imaging of pancreatic adenocarcinomas:association with histopathology and tumor grade. J Magn ResonImaging 2011; 33: 136-142 [PMID: 21182131 DOI: 10.1002/jmri.22414].
  • 6Chen X, Li WL, Zhang YL, Wu Q, Guo YM, Bai ZL. Meta-analysisof quantitative diffusion-weighted MR imaging in the differentialdiagnosis of breast lesions. BMC Cancer 2010; 10: 693 [PMID:21189150 DOI: 10.1186/1471-2407-10-693].
  • 7Fattahi R, Balci NC, Perman WH, Hsueh EC, Alkaade S, HavliogluN, Burton FR. Pancreatic diffusion-weighted imaging (DWI):comparison between mass-forming focal pancreatitis (FP), pancreaticcancer (PC), and normal pancreas. J Magn Reson Imaging 2009; 29:350-356 [PMID: 19161187 DOI: 10.1002/jmri.21651].
  • 8Kamisawa T, Takuma K, Anjiki H, Egawa N, Hata T, Kurata M,Honda G, Tsuruta K, Suzuki M, Kamata N, Sasaki T. Differentiationof autoimmune pancreatitis from pancreatic cancer by diffusionweightedMRI. Am J Gastroenterol 2010; 105: 1870-1875 [PMID:20216538 DOI: 10.1038/ajg.2010.87].
  • 9van Pul C, Roos FG, Derksen OS, Buijs J, Vlaardingerbroek MT,Kopinga K, Wijn PF. A comparison study of multishot vs. singleshotDWI-EPI in the neonatal brain: reduced effects of ghostingcompared to adults. Magn Reson Imaging 2004; 22: 1169-1180[PMID: 15607088 DOI: 10.1016/j.mri.2004.09.002].
  • 10Wu LM, Hu JN, Hua J, Liu MJ, Chen J, Xu JR. Diagnostic valueof diffusion-weighted magnetic resonance imaging compared withfluorodeoxyglucose positron emission tomography/computedtomography for pancreatic malignancy: a meta-analysis using ahierarchical regression model. J Gastroenterol Hepatol 2012; 27:1027-1035 [PMID: 22414092 DOI: 10.1111/j.1440-1746.2012.07112.x].

同被引文献25

引证文献5

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部