期刊文献+

Newly designed “pieced” stent in a rabbit model of benign esophageal stricture

Newly designed “pieced” stent in a rabbit model of benign esophageal stricture
下载PDF
导出
摘要 AIM:To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture.METHODS:Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation.Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups.The control group(n = 15) was implanted with a conventional stent,and the study group(n= 15) was implanted with a detachable "pieced" stent.The study stent(30 mm in length,10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines.The stent was collapsed by pulling the suture lines out of the mesh.Two weeks after stricture formation,endoscopic placement of a conventional stent or the new stent was performed.Endoscopic extraction was carried out four weeks later.The extraction rate,ease of extraction,migration,complications,and survival were evaluated.RESULTS:Stent migration occurred in 3/15(20%)animals in the control group and 2/15(13%) animals in the study group;the difference between the two groups was not statistically significant.At the end of four weeks,the remaining stents were successfully extracted with the endoscope in 100%(11/11) of the animals in the study group,and 60%(6/10)of the animals in the control group;this difference was statistically significant(P < 0.05).There was no difference in the mean number of follow-up days between the control and study groups(25.33 vs25.85).Minor bleeding was reported in five cases in the study group and four in the control group.There were no severe complications directly associated with stent implantation or extraction in either of the two groups.CONCLUSION:In this experimental protocol of benign esophageal strictures,the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent. AIM:To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture.METHODS:Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation.Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups.The control group(n = 15) was implanted with a conventional stent,and the study group(n= 15) was implanted with a detachable 'pieced' stent.The study stent(30 mm in length,10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines.The stent was collapsed by pulling the suture lines out of the mesh.Two weeks after stricture formation,endoscopic placement of a conventional stent or the new stent was performed.Endoscopic extraction was carried out four weeks later.The extraction rate,ease of extraction,migration,complications,and survival were evaluated.RESULTS:Stent migration occurred in 3/15(20%)animals in the control group and 2/15(13%) animals in the study group;the difference between the two groups was not statistically significant.At the end of four weeks,the remaining stents were successfully extracted with the endoscope in 100%(11/11) of the animals in the study group,and 60%(6/10)of the animals in the control group;this difference was statistically significant(P < 0.05).There was no difference in the mean number of follow-up days between the control and study groups(25.33 vs25.85).Minor bleeding was reported in five cases in the study group and four in the control group.There were no severe complications directly associated with stent implantation or extraction in either of the two groups.CONCLUSION:In this experimental protocol of benign esophageal strictures,the novel 'pieced' stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.
出处 《World Journal of Gastroenterology》 SCIE CAS 2015年第28期8629-8635,共7页 世界胃肠病学杂志(英文版)
基金 Supported by A grant from the Graduate Innovation Foundation of Shandong University,China,No.yyx10129
关键词 Animal EXPERIMENTATION Detachable 'pieced'stent Endoscopic procedure ESOPHAGEAL STRICTURE Stentremoval Animal experimentation Detachable 'pieced' stent Endoscopic procedure Esophageal stricture Stent removal
  • 相关文献

参考文献1

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部