图像引导自适应放疗在宫颈癌治疗中的应用 被引量:5

下载PDF
导出
摘要 目的观察图像引导自适应放疗(IGART)在宫颈癌治疗中的应用效果。方法接受放疗的宫颈癌患者14例,借助4D CT扫描图像设计放疗计划及剂量,放疗过程中采用锥形束CT(CBCT)扫描,获取用于IGART的图像。放疗前采用CBCT进行位置验证扫描,并将获取的CBCT图像与计划CT图像进行3D-3D配准,测量患者的摆位误差。借助CBCT图像勾画放疗过程中的肿瘤靶区(PTV),评价计划靶区(PTV)对GTV的覆盖情况。结果 14例患者共执行131次CT扫描,其中治疗前扫描95次,在线匹配后验证扫描36次。在治疗前95次扫描中,患者头脚、前后和左右方向的摆位误差分别为(0.38±0.07)、(0.30±0.09)、(0.28±0.10)cm。36次验证扫描后,患者头脚、前后和左右方向的摆位误差均减少(P均<0.05)。患者分次放疗期间,CBCT图像与计划CT图像匹配修正前GTV溢出PTV 6次,未覆盖率为6.3%(6/95),匹配修正后分别为2次和2.1%。结论 IGART用于宫颈癌治疗可减少并修正患者的摆位误差,降低肿瘤靶区脱靶的发生率,缩小临床靶区的外扩边界。
出处 《山东医药》 CAS 北大核心 2015年第27期38-39,共2页 Shandong Medical Journal
  • 相关文献

参考文献13

  • 1Qin A,Sun Y,Liang J,et al.Evaluation of online/offline image guidance/adaptation approaches for prostate cancer radiation therapy[J].Int J Radiat Oncol Biol Phys,2015,91(5):1026-1033.
  • 2Maund IF,Benson RJ,Fairfoul J,et al.Image-guided radiotherapy of the prostate using daily CBCT:the feasibility and likely benefit of implementing a margin reduction[J].Br J Radiol,2014,87(1044):20140459.
  • 3张基永,陆佳扬,洪丹丽.4D-CT模拟机定位床和激光定位灯的质量保证[J].医疗装备,2013,26(6):1-2. 被引量:3
  • 4Toita T,Ohno T,Kaneyasu Y,et al.A consensus-based guideline defining clinical target volume for primary disease in external beam radiotherapy for intact uterine cervical cancer[J].Jpn J Clin Oncol,2011,41(9):1119-1126.
  • 5Lim K,Small W Jr,Portelance L,et al.Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy for the definitive treatment of cervix cancer[J].Int J Radiat Oncol Biol Phys,2011,79(2):348-355.
  • 6Small W Jr,Mell LK,Anderson P,et al.Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy in postoperative treatment of endometrial and cervical cancer[J].Int J Radiat Oncol Biol Phys,2008,71(2):428-434.
  • 7Ahmad R,Hoogeman MS,Bondar M,et al.Increasing treatment accuracy for cervical cancer patients using correlations between bladder-filling change and cervix-uterus displacements:proof of principle[J].Radiother Oncol,2011,98(3):340-346.
  • 8Whitfield G,Jain P,Green M,et al.Quantifying motion for pancreatic radiotherapy margin calculation[J].Radiother Oncol,2012,103(3):360-366.
  • 9Tyagi N,Lewis JH,Yashar CM,et al.Daily online cone beam computed tomography to assess interfractional motion in patients with intact cervical cancer[J].Int J Radiat Oncol Biol Phys,2011,80(1):273-280.
  • 10Vande BL,Schulz IM,Kort GA,et al.Motion and deformation of the target volumes during IMRT for cervical cancer[J].Radiother Oncol,2008,88(2):233-240.

二级参考文献4

  • 1邓小武,黄劭敏,祁振宇.CT模拟机的质量控制和质量保证检验[J].中国肿瘤,2004,13(9):546-550. 被引量:33
  • 2AAPM REPORT NO. 66. Quality assurance for computed - tomography simulators and the computed - tomography - simulation process [ J ] . Medical Physics, 2003, 10 (30) : 2762 - 2792.
  • 3Nishidai T, Nagata Y, Takahashi M, et al. CT simulator: A new 5 - D planning and simulating system for radiothera- py [J] . Radiat Oncol Biol Phys, 1990, 18:499 -504.
  • 4贾明轩,邹华伟,聂海峰,徐兆国,吴荣.CT模拟定位精度的影响因素探讨[J].中华放射肿瘤学杂志,2002,11(1):21-22. 被引量:29

共引文献2

同被引文献39

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部