期刊文献+

Transportation characteristics of gas-solid two-phase flow in a long-distance pipeline 被引量:5

Transportation characteristics of gas-solid two-phase flow in a long-distance pipeline
原文传递
导出
摘要 In this study, experiments on fly ash conveying were carried out with a home-made long-distance positive-pressure pneumatic conveying system equipped with a high performance electrical capacitance tomography system to observe the transient characteristics of gas-solid two-phase flow. The experimen- tal results indicated that solids throughput increased with increasing solids-gas ratio when the conveying pipeline was not plugged. Moreover, the optimum operating state was determined for the 1000 m long conveying pipeline with a throttle plate of 26 orifices. At this state the solids throughput was about 12.97 t/h. Additionally, the transportation pattern of fly ash gradually changed from sparse-dense flow to partial and plug flows with increasing conveying distance because of the conveying pressure loss, These experimental results provide important reference data for the development of pneumatic conveying technology. In this study, experiments on fly ash conveying were carried out with a home-made long-distance positive-pressure pneumatic conveying system equipped with a high performance electrical capacitance tomography system to observe the transient characteristics of gas-solid two-phase flow. The experimen- tal results indicated that solids throughput increased with increasing solids-gas ratio when the conveying pipeline was not plugged. Moreover, the optimum operating state was determined for the 1000 m long conveying pipeline with a throttle plate of 26 orifices. At this state the solids throughput was about 12.97 t/h. Additionally, the transportation pattern of fly ash gradually changed from sparse-dense flow to partial and plug flows with increasing conveying distance because of the conveying pressure loss, These experimental results provide important reference data for the development of pneumatic conveying technology.
出处 《Particuology》 SCIE EI CAS CSCD 2015年第4期196-202,共7页 颗粒学报(英文版)
基金 the financial support from the National Science and Technology Support Program of China(no.2012BAB13B04)
关键词 Pneumatic conveying Electrical capacitance tomography Fly ash Gas-solid two-phase flow Solid concentration Pneumatic conveying Electrical capacitance tomography Fly ash Gas-solid two-phase flow Solid concentration
  • 相关文献

参考文献5

二级参考文献36

  • 1朱学明,王化祥,张立峰.低通滤波器对电容成像系统实时性影响研究[J].仪器仪表学报,2004,25(6):816-819. 被引量:7
  • 2董向元,陈琪,李惊涛,蔡斌,阎润生,王海刚,刘石.基于快速投影LANDWEBER法的电容层析成像图像重建算法研究[J].中国电机工程学报,2005,25(14):89-92. 被引量:29
  • 3Isaksen Φ. A review of reconstruction techniques for capacitance tomography[J]. Measurement Science and Technology, 1996, 7(3): 325-37.
  • 4Dobson D C, Santosa F. An image-enhancement technique for electrical impedance tomography[J]. Inverse Problems, 1994, 10(2): 317-334.
  • 5Rudin L I, Osher S, Fatemi E. Nonlinear total variation based noise removal algorithms[J]. PhysicaD, 1992, 60(1-4): 259-268.
  • 6Strong D M, Chan T F. Edge-preserving and scale-dependent properties of total variation regularization[J]. Inverse Problems, 2003, 19(6): 165-187.
  • 7Yang W Q. Hardware design of electrical capacitance tomography systems[J]. Measurement Science and Technology, 1996, 7(3): 225-232.
  • 8Yang W Q, York T A. New AC-based capacitance tomography system[J]. IEE Proc.-Sci. Meas. Technol., 1999, 146(1): 47-53.
  • 9唐磊.电学成像系统图像重建算法研究及可视化软件设计[D].天津:天津大学,2008.
  • 10Huang S M, Plaskowski A, Xie C G, et al. Capacitance-based tomographic flow imaging system[J]. Electron. Lett., 1998, 24(7): 418-419.