期刊文献+

腓骨肌皮瓣重建颌骨缺损中微血管吻合器的应用 被引量:3

Application of microvascular anastomotic device for fibular flap transfer in reconstruction of oral and maxillofacial defects
下载PDF
导出
摘要 目的 :探讨微血管吻合器在腓骨肌皮瓣重建颌骨缺损中的应用效果。方法:22例腓骨肌皮瓣在修复口腔颌面部术后缺损中应用微血管吻合器用于静脉端-端吻合,共用32个吻合器。结果:微血管吻合器适用于腓骨肌皮瓣的静脉端-端吻合,平均吻合时间为3.5~9 min,明显缩短了手术时间。皮瓣均移植成功,未出现危象或血栓。结论:微血管吻合器在腓骨肌皮瓣重建颌骨缺损中吻合质量可靠,可明显缩短手术时间,具有较高的临床应用价值。 PURPOSE: To evaluate the role of microvascular anastomotic device in fibular flap transfer for reconstruction of oral and maxillofacial defects. METHODS: Twenty-two patients with oral and maxillofacial defects were repaired with fibular flap. The microvascular anastomotic device was applied to perform venous anastomosis in these cases. RESULTS:There was no flap losses due to venous thrombosis. The average time of venous anastomosis was 3.5-9 min.CONCLUSIONS: The microvascular anastomotic device can significantly shorten the anastomosis when compared with the standard suture techniques.
出处 《中国口腔颌面外科杂志》 CAS 2015年第4期348-351,共4页 China Journal of Oral and Maxillofacial Surgery
关键词 口腔颌面部 腓骨肌皮瓣 微血管吻合器 静脉吻合 Oral and maxillofacial region Fibular flap Microvascular anastomotic device Venous anastomosis
  • 相关文献

参考文献7

二级参考文献39

共引文献210

同被引文献33

  • 1Coon D,Chen L,Boctor EM,et al.Proof-of-concept studies for markerbased ultrasound doppler analysis of microvascular anastomoses in a modified large animal model[J].J Reconstr Microsurg,2015,12(19):194-197.doi:10155/s-0035-1568158.
  • 2Patel UA,Lin AC.Flap outcomes when training residents in microvascular anastomosis in the head and neck[J].Am J Otolaryng,2013,34(5):407-410.doi:10.1016/j.amjoto.2013.02.005.
  • 3Chao AH,Meyerson J,Povoski SP,et al.A review of devices used in the monitoring of microvascular free tissue transfers[J].Expert Rev Med Devices,2013,10(5):649-660.doi:10.1586/17434440.2013.827527.
  • 4Lundgren TK,Wei FC.Oversized design of the anterolateral thigh flap for head and neck reconstruction[J].J Craniofac Surg,2013,24(1):134-135.doi:10.1097/SCS.0b013e318268d273.
  • 5Tahirbegi IB,Mir M,Schostek S,et al.In vivo ischemia monitoring array for endoscopic surgery[J].Biosens Bioelectron,2014,61(15):124-130.doi:10.1016/j.bios.2014.02.080.
  • 6Ardehali B,Morritt AN,Jain A.Systematic review:anastomotic microvascular device[J].J Plast Reconstr Aesthet Surg,2014,67(6):752-755.doi:10.1016/j.bjps.2014.01.038.
  • 7Clarke-Pearson EM,Kim PS.An effective method to access recipient vessels outside the zone of injury in free flap reconstruction of the lower extremity[J].Ann Plas Surg,2014,73(Suppl 2):S136-138.doi:10.1097/SAP.0000000000000202.
  • 8Huang SF,Wang TH,Wang HW,et al.Design,manufacture and in-vitro evaluation of a new microvascular anastomotic device[J].Conf Proc IEEE Eng Med Biol Soc,2013:1831-1834.doi:10.1109/EMBC.2013.6609879.
  • 9Camara O,Herrmann J,Egbe A,et al.Venous coupler forfree-flap anastomosis[J].Anticanc Res,2009,29(7):2827-2830.
  • 10Kuo YR,Jeng SF,Lin KM,et al.Microsurgical tissue transfers for head and neck reconstruction in patients with alcohol-induced mental disorder[J].Ann Surg Oncol,2008,15(1):371-377.

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部