期刊文献+

带有能源塔的自复叠热泵系统及其热力分析 被引量:5

Thermodynamic analysis of heat pump system with energy tower based on auto cascade refrigeration circle
原文传递
导出
摘要 提出一种将闭式能源塔热泵技术与自复叠系统相结合的热泵系统,该系统在保证提供55℃热水的前提下,利用自复叠系统-39℃^-14℃的蒸发温度,通过能源塔提取空气能,实现冬季寒冷地区的能量传递,系统运行中通过制冰浓缩方式控制乙二醇喷淋液的浓度;通过REFPROP软件,进行了该热泵系统的热力分析;分析表明,系统具有较好的可行性。 A heat pump system of the combination of a closed type of energy tower heat pump technology and the auto cascade system was presented in this paper. Based on auto - cascade system with an evaporation temperatures of 39℃ to 14℃, the system could provide heat water at 55℃, extract low heat source in the air throughout the energy tower and transport energy be- tween regions. Meanwhile, it controls ice concentration of ehylene glycol. Then, based on the REFPROP software, the analysis of the thermodynamic properties of the system was completed and the feasibility of the design was determined.
出处 《低温与超导》 CAS 北大核心 2015年第8期77-82,共6页 Cryogenics and Superconductivity
基金 国家自然科学基金(U1304521) 河南科技大学科技创新团队(2015XTD004)
关键词 热泵 自复叠 能源塔 热力性质 浓度控制 制冰 Heat pump, Auto cascade, Energy tower, Thermodynamic property, Consistency control, Ice concentration
  • 相关文献

参考文献9

  • 1杜垲,徐卫荣.R134a/R123自然复叠式热泵系统浓度配比分析[J].制冷学报,2009,30(2):33-38. 被引量:15
  • 2Tangwe S,Simon M, Meyer E L, et al. Performance optimization of an air source heat pump water heater using mathematical modelling[ J]. Journal of Energy in South- ern Africa, 2015,26:96 - 105.
  • 3芮胜军,卢向华,梁坤峰,李健.自复叠热泵冷凝器设计[J].河南科技大学学报(自然科学版),2013,34(2):30-33. 被引量:3
  • 4Du Kai, Zhang Shaoqian, Xu Weirong, et al. A study on the cycle characteristics of an auto - cascade refrigera- tion system [ J ]. Experimental Thermal and Fluid Sci- ence, 2009,33 : 240 - 245.
  • 5王玉珏,黎立新,季建刚.非共沸工质自复叠制冷技术研究现状[J].制冷与空调,2008,8(6):22-26. 被引量:7
  • 6Gong Maoqiong, Wu Jianfeng, Luo Ercang. Study of the single- stage mixed -gases refrigeration cycle for cool- ing temperature - distributed heat loads[ J]. Internation- al Journal of Thermal Sciences, 2004,43 : 31 - 41.
  • 7张晨,杨洪海,刘秋克,吴建兵.闭式热源塔用作空调冷热源的分析[J].建筑热能通风空调,2009,28(6):71-73. 被引量:17
  • 8Liang Caihua, Wen Xiantai, Liu Chengxing, et al. Per- formance analysis and experimental study of heat - source tower solution regeneration[ J]. Energy Conver- sion and Management, 2014,85:596 - 602.
  • 9Vieira Stewart Beal. Air source heat pump water heat- ers in residential buildings in Australia:Identification of key performance parameters [ J ]. Energy and build- ings, 2015,91 : 148 - 162.

二级参考文献49

共引文献38

同被引文献32

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部