摘要
以温州某炸药雷管仓库为例,介绍火工品存放区域的防雷设计,阐述炸药、雷管库双针等高接闪杆保护范围、安全距离的计算、防闪电感应、防静电感应、防闪电电涌侵入、防接触电压和跨步电压、等电位连接措施的设计要求,以期为炸药、雷管库及第一类防雷建筑物的防雷设计提供参考。
With the example of a dynamite detonator warehouse in Wenzhou, lightning protection design of pyrotechnics storage area is introduced. In order to provide a reference for the lightning protection design of explosives, detonators library and the first class of mine buildings, the explosive, detonator library, such as double needle high flash rod the scope of protection, the calculation of safety distance, anti lightning induction, electrostatic induction, lightning surge anti invasion and anti contact voltage and the step voltage, potential connection measures in the design requirements are described.
出处
《智能建筑电气技术》
2015年第4期38-42,共5页
Electrical Technology of Intelligent Buildings
关键词
防雷
接闪杆
保护范围
安全距离
lightning protection, lightning rod, protective range, safe distance