宽动态范围红外测量系统的快速非均匀性校正 被引量:19

Fast non-uniformity correction for high dynamic infrared radiometric system
下载PDF
导出
摘要 宽动态范围的红外辐射特性测量系统往往预设多个积分时间档位,并对每个积分时间逐一进行非均匀性校正。本文研究了不同积分时间下非均匀性校正系数有的差异问题,基于黑体定标法和积分时间法提出了新的非均匀性校正方法。该方法只需要得到两个积分时间和两个定标温度点即可得到全动态范围所有积分时间下的非线性校正系数,可在保证校正精度的同时减少辐射源温度点,降低校正时间。使用某Φ400mm口径的地基红外辐射特性测量系统对该方法进行了验证。结果表明,采用本文方法后图像的非均匀性由3.78%减小到0.24%。由4ms下的校正数据可知,得到的校正结果接近直接用该积分时间进行校正的精度。提出的方法简化了所需设备,降低了校正时间,具有实时性强、精度高等特点,适用于外场测量。 Several different integration time steps are often required for a high dynamic infrared radio- metric system, therefore, its non-uniformity is usually corrected one by one. As there are different correction coefficients in different time, this paper proposes a new non-uniformity correction method based on blackbody calibration method and integration time calibration method. The method obtains nonlinear correction coefficients of all integration time in whole dynamic ranges only by two integra- tion time steps and two calibration temperature points, meanwhile keeping correction accuracy, reduc- ing measuring temperature points and correction time. The verifying experiments for the proposed method are performed by using a Ф400 mm ground-based infrared radiometric system. The results show that the uniformity has reduced from 3.78% to 0.24% by using the proposed method. In addition, the result at 4 ms integration time illustrates that this method has a higher precision. Moreover,it greatly reduces the required equipment and correction time,and is characterized by good real-time performance and suitable for field measurements.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2015年第7期1932-1938,共7页 Optics and Precision Engineering
基金 国家863高技术研究发展计划资助项目(No.2011AA8082035)
关键词 制冷型红外探测器 辐射测量术 动态范围 积分时间 非均匀性校正 cooled infrarect detctor radiometry dynamic range integration timel non-uniformity correction
  • 相关文献

参考文献11

  • 1CAO Y P,TISSE C L. Single-image-based solution for optics temperature-dependent nonuniformity correction in an uncooled long-wave infrared camera[J]. Optics Letters, 2014,39(3):646-648.
  • 2白俊奇,陈钱,钱惟贤,屈惠明,王娴雅,左超.基于环境温度的红外焦平面阵列非均匀性校正[J].红外与毫米波学报,2010,29(1):49-52. 被引量:13
  • 3VENKATESWARLU R, Er M H, GAN Y H,et al.. Nonuniformity compensation for IR focal plane array sensors [J]. SPIE, 1997, 3061: 0277-788X.
  • 4LEATHERS R A, DOWNES T V, PRIEST R, et al.. Scene-based nonuniformity corrections for optical and SWIR pushroom sensors[J]. Optics Express, 2005, 13(13): 5136-5150.
  • 5OCHS M, SCHULZ A, BAUER H J. High dynamic range infrared thermography by pixelwise radiometric self calibration[J]. Infrared Physics & Technology, 2010,53:112-119.
  • 6SVENSSON T, RENHORN I. Evaluation of a method to radiometric calibrate hot target image data by using simple reference sources close to ambient temperature[J]. SPIE,2010, 7662:76620.
  • 7MERMELSTEIN M D, SNAIL K A, PRIEST R G. Spectral and radiometric calibration of midwave and longwave infrared cameras[J]. Opt. Eng., 2000,39: 347-352.
  • 8WOLFE W L. Introduction to Radiometry [M]. Bellingham: SPIE, 1998.
  • 9HOLST G C. Testing and Evaluation of Infrared Imaging Systems[M]. Bellingham: JCD, 1933.
  • 10李宁,杨词银,曹立华,郭立红.3~5μm红外焦平面阵列的辐射定标[J].光学精密工程,2011,19(10):2319-2325. 被引量:29

二级参考文献17

共引文献39

同被引文献146

引证文献19

二级引证文献67

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部